Koldfront PACI12020HSV Скачать руководство пользователя страница 17

 

12 

 

 

 

 

INSTALLING THE BATTERIES 

1.

 

Remove the cover on the back of the remote control.  

2.

 

Insert the batteries with the (+) and (-) ends pointing in the correct direction. 

3.

 

Slide the cover back on. 

 

 

 

 

REMOTE CONTROL LCD INDICATORS

 

 
 
 

 

 

 

 

Indicators 

 

Transmitter 

This indicator appears when the Power or Timer button is signaling the unit. 

Fan Speed 

This indicator shows the set fan speed between   Automatic,   High,              

 Medium, and   Low. 

Mode 

This indicator shows the set mode between   Automatic,   Cooling,                

 Dehumidify,   Fan Only, and   Heat. 

Temperature Setting 

This indicator shows the set temperature. 

Fahrenheit and Celsius 

This indicator shows if the set temperature is in Fahrenheit or Celsius. 

Clock 

This indicator shows the Clock’s time. The remote control has a 24-Hour 
clock. 

Timed Hours 

This indicator shows the number of timed hours when the Timer is enabled. 

Timer 

This indicator shows if the On Timer or Off Timer is enabled. 

 

 

Caution: Use only AAA batteries. Remove the batteries if the remote control will not be used for one month 
or longer. Do not attempt to recharge batteries not designed to be recharged. All batteries should be 
replaced at the same time. Do not mix old and new batteries. Do not dispose of batteries in a fire as they 
may explode. 

Содержание PACI12020HSV

Страница 1: ...ioner PACI12020HSV Owner s Manual For more information on other great Koldfront or EdgeStar products on the web go to http www edgestar com To use the self diagnostic tool go to https support edgestar...

Страница 2: ...priate amperage If the power cord is damaged it must be replaced by the manufacturer a service agent or a qualified technician Do not remove any part of the casing unless you are instructed to do so b...

Страница 3: ...power cord to a grounded outlet 2 Press the TEST button on the LCDI plug This should trip the plug and cut the power to the air conditioner If the plug does not trip and you are able to turn on the u...

Страница 4: ...TO THE EXHAUST HOSE 6 CONNECTING THE DUCT CONNECTOR TO THE UNIT 6 CONNECTING THE DUCT CONNECTOR TO THE GRATED ADAPTER 7 NOTES ABOUT THE EXHAUST HOSE 7 Draining the Unit 8 DRAINAGE OPTIONS 8 Operation...

Страница 5: ...d packaging materials in case you need to move or ship the appliance in the future Allow the unit to stand for at least 24 hours before you use it this allows the cooling components time to settle fro...

Страница 6: ...label on the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service und...

Страница 7: ...2 Parts Identification FRONT VIEW BACK VIEW Caution Make sure the drain plug is firmly installed before using the unit to prevent leaking...

Страница 8: ...you begin make sure you have all the parts necessary for installation WINDOW KIT PARTS LIST PARTS FOR CONTINUOUS AND MISTING DRAINAGE Note There is one duct connector that includes an opening for the...

Страница 9: ...conditioner Your window kit can be installed on a horizontal or vertical sliding window as shown in the following pictures INSTALLING THE GRATED ADAPTER 1 Insert the round grated adapters through the...

Страница 10: ...DOW PLATES 3 Open your window and place the window kit on the window sill with the grooved side facing outward Then slide the window kit plate to fit the width of the window You can use screws to secu...

Страница 11: ...ps 6 Roll the unit towards the window kit Leave a space that is at least 20 inches to the wall CONNECTING THE DUCT CONNECTOR TO THE UNIT 7 Align the slots on the duct connector to the tabs and snap th...

Страница 12: ...ill be expelled out of the exhaust port of the unit Please take this into account when deciding how to vent it 1 The exhaust hose supplied with the portable air conditioner can be extended up to 48 in...

Страница 13: ...mode The unit will do this automatically This mode will be sufficient for most environments If you are operating the unit in an environment with higher levels of humidity you may choose one of the ot...

Страница 14: ...installed on the exhaust outlet of the unit If the adapter is not installed in this position you will need to adjust the adapters Run the excess water line into the cavity of the exhaust hose 3 Connec...

Страница 15: ...and not back into the exhaust hose The unit will now automatically mist any excess water to the outside Installing the mist system in the exhaust hose ensures all of the moisture is pushed completely...

Страница 16: ...e This button sets the mode The Automatic Cool Dehumidify Fan or heat indicator will appear depending on the mode you set Down This button decreases the Temperature Timer or Clock settings Clock This...

Страница 17: ...e Setting This indicator shows the set temperature Fahrenheit and Celsius This indicator shows if the set temperature is in Fahrenheit or Celsius Clock This indicator shows the Clock s time The remote...

Страница 18: ...the air conditioner will restart itself in its last used mode settings once power is restored The compressor will restart after 3 minutes Cooling Mode Cooling mode cools and dehumidifies the air If t...

Страница 19: ...ure the power cord is plugged into a power outlet 2 Press the Power button on the remote control 3 Press the Mode button until the Fan Only indicator is selected 4 Press the Speed button to select the...

Страница 20: ...ttons Holding down the buttons longer than 1 second will change the time in fast mode The clock is a 24 Hour clock so if it is 6 00 PM you would set the time to be 18 00 3 To save your settings press...

Страница 21: ...ed hour indicator will stop blinking The unit will automatically turn off after the selected time elapses FRONT PANEL LIGHTS AND CONTROLS Front Panel Lights Your portable air conditioner has a front p...

Страница 22: ...e pre filter 2 Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt then rinse thoroughly under lukewarm running water below 104 F You may use a mild soap and water solution if...

Страница 23: ...e set the timer to turn on the unit in cooling mode for 3 or more hours to cool the room before you arrive You may want to operate the unit all day if you live in a warmer climate Minimize the heat so...

Страница 24: ...ll the batteries correctly The remote control is defective Contact customer service My air conditioner is making a loud noise The unit is not level Make sure the unit is on a level surface A foreign o...

Страница 25: ...nit There are open windows and doors Close any open doors and windows There are too many heat sources Remove or shut off additional heat sources such as radio equipment servers etc The room garage may...

Страница 26: ...LING CAPACITY SACC 5500 BTU COOLING CAPACITY ASHRAE 12000 BTU COLOR Silver and Grey COOLANT R410A TIMER 24 Hour DIMENSIONS HEIGHT X WIDTH X DEPTH 29 3 16 X 17 1 8 X 15 1 8 NET WEIGHT 69 Pounds Note Te...

Страница 27: ...different standard ASHRAE that produced a higher cooling capacity output While the SACC BTU s are lower than the previous ASHRAE BTU s the construction and cooling capacity of this model s remains unc...

Страница 28: ...idents acts of God vermin fire flood improper installation unauthorized service maintenance negligence unauthorized installation or modification or rental or commercial use Labor service transportatio...