Handling and Safety Precautions
These precautions should be strictly observed in order to ensure safe,
long-term use of the product.
The following precautions should be observed particularly strictly:
1. This simulator is made to have the same feel as that of a living body. Undue handling may cause
breakage of the simulator.
2. This model has a distinctive odor resulting from the materials it is made from however is not
harmful to the body or indicate any problem with quality. This distinctive odor will weaken over
time. The product is also coated in baby powder at the time of manufacture and the smell of
baby powder may remain on the product.
3. When you practice cleaning or disinfecting of the pubic area, please use water. Use of alcohol
may cause breakage of the simulator.
Use of colored disinfectant liquid may cause pigment to be fixed to the simulator so that the
pigment cannot be removed.
4. As for the lubricant, please use K-Y
tm
lubricating jelly. Please do not use K-Y® gel, as it may
increase the insertion resistance of the catheter.
5. Please do not use oily lubricant (olive oil etc.), alcohol lubricant, and lubricant containing organic
solvent. These may cause breakage of the simulator.
6. Please use catheters of 14Fr and 16Fr.
7. Please check the state of the catheter before inserting the catheter. Please do not use a catheter
that is degraded or deformed. Such a catheter is difficult to insert.
8. When inserting the catheter, please apply the lubricant each time.
9. If it is difficult to insert the catheter, please increase the amount of the lubricant to be applied
or use another catheter (firm silicone catheter or catheter with thinner baloon part etc). The
simulator may break if such a catheter is forced to be inserted.
10. When indwelling the catheter, please inflate the balloon after inserting the catheter apart from
the balloon end portion by a distance equal to or greater than 4 cm. Indwelling of the catheter
in an intermediate of the valve causes the valve and the catheter to be broken. Please provide a
marker on the catheter before commencing training to ensure that the catheter tip is inserted by
a distance equal to or greater than 4 cm before inflating the balloon.
4cm
Marker