1. Description & features 

Description 

With this LM-098 simulator, infant vital signs can be measured and the entire body can be 
monitored. A crying-sound function reproduces the clinical setting more realistically, while heart 
and breathing sounds can be checked, enabling hands-on training of measurement and monitoring 
close to those of the actual clinical site.

Features

Control box

Heart and respiratory rates

・  Heart rate and respiratory rate are displayed digitally over a normal range, and the status of 

the infantcan be easily set by turning a rotary dial.

Heart sounds and breathing sounds

・  An external speaker provided on the control box make these sounds audible in the nearby 

environment.

・  The sounds can be set independently, so the balance can be adjusted to match the status 

settings.

・  Highly realistic sounds are produced with clear sound quality.

Crying-sound function

・  Four different crying patterns can be reproduced.
・  Four buttons are provided to enable direct operation.

  * The LM-098's four crying sound buttons are intended to simulate the following meanings: 
  1)hungry; 2) sleepy; 3) "hold me"; 4) comfortable. 
  Please note, however, that crying sounds differ among infants and the crying sounds produced by the  

LM-098 are intended solely as a reference.

Neonatal simulator

Full-body monitoring

・  Silicone rubber is used to produce an extremely realistic texture.
・  Monitoring of the head area (palpation of skull molding) includes locating the anterior  

fontanel, posterior fontanel, sagittal suture, and coronal suture.

・  A rectal thermometer can be inserted.

Auscultation

・  Vital sign measurement includes auscultation of heart and breathing sounds.

Содержание LM-098

Страница 1: ...tal Signs Simulator II Please read this instruction manual carefully to ensure correct use of the product and store it in a safe place for easy access KOKEN CO LTD 1 4 14 Koraku Bunkyo ku Tokyo 112 00...

Страница 2: ......

Страница 3: ...o the simulator as doing so may cause it to malfunction 4 Be careful not to bend twist or step on the connecting cord or power supply cord in order to prevent disconnection 5 Be careful not to drop th...

Страница 4: ...use store the simulator in the carrying case away from direct sunlight or ultraviolet light 1 The contents of this instruction manual are subject to change without notice 2 This instruction manual ma...

Страница 5: ...3 Table of Contents 1 Outline and Features 2 Components and Configuration 3 Handling the Simulator 4 Simulator Configuration Charts 5 Specifications...

Страница 6: ...independently so the balance can be adjusted to match the status settings Highly realistic sounds are produced with clear sound quality Crying sound function Four different crying patterns can be rep...

Страница 7: ...5 Visual inspection Thoracoabdominal breathing synchronized to the set respiratory rate can be observed visually Crying sound function The sound of crying can be heard coming from the mouth...

Страница 8: ...n View of simulator components 1 Neonatal Simulator with connecting cord 2 Control box 3 AC Adapter with DC cord 4 AC cord If necessary prepare an appropriate plug adapter according to the wall socket...

Страница 9: ...Thoracoabdominal movement On Off button 4 Heart rate adjustment dial 5 Respiratory rate adjustment dial 6 Heart sound volume dial 7 Breathing sound volume dial 8 Crying sound volume dial 9 External s...

Страница 10: ...box rear view 1 Cable connector 2 Power switch 3 Power inlet Monitor 1 Heart rate display 2 Respiratory rate display 3 Crying sound setting display 4 Thoracoabdominal movement setting display On Off 1...

Страница 11: ...9 Neonatal simulator 1 Connecting cord Cannot be disconnected from the simulator 2 Breathing sound internal speaker 3 Heart sound internal speaker 4 Thoracoabdominal movable part 1 2 3 4...

Страница 12: ...and each function starts operating 7 Adjust the heart and respiratory rates and volume to the desired level by turning the respective dials 8 Thoracoabdominal movement is controlled by pressing the c...

Страница 13: ...ominal movement to better distinguish heart and breathing sounds Turn the dial to adjust the heart rate within the range of 100 180 beats per minute Turn the dial to adjust the respiratory rate within...

Страница 14: ...Control box 1 AC adapter with DC cord 1 AC cord 1 Storage bag 1 Instruction manual this document 1 5 Specifications Height Weight Head circumference Approx 48 cm Approx 2 700 g Approx 34 cm Neonatal s...

Отзывы: