Handling and Safety Precautions

These precautions should be strictly observed in order to ensure safe, 

long-term use of the product.

The following precautions should be observed particularly strictly:

1.  This model is made of special silicone.  Improper handling may break the model. 
2.  Do not place any object on the bronchial unit as this may deform the unit. 
3.  To remove stubborn stains on the model, use gauze or the like that has been soaked with water 

or neutral detergent diluted with water.  Do not use thinner, benzine, or any other solvent as this 
may cause the LM-092 to lose color or become deformed. 

4.  To remove stains inside of the box, wipe it using gauze soaked with water or neutral detergent 

diluted with water.  Do not use thinner, benzine, or any other solvent. 

5.  Never use oil-based ink or paint as these will infiltrate the LM-092 and any contamination will not 

be removed successfully. 

6.  In storing the LM-092, choose a location where it is not exposed to direct sunlight or ultraviolet 

rays.  (The LM-092 will be discolored if exposed to direct sunlight or ultraviolet rays for long 
hours.) 

7.  If the LM-092 is not used, store it by placing it in the box and close the cover of the box. 
8.  Lubricant (silicone spray) is not included in the kit. Follow the precautions below for use.

Содержание LM-092

Страница 1: ...nchoscopy Training Model Please read this instruction manual carefully to ensure correct use of the product and store it in a safe place for easy access KOKEN CO LTD 1 4 14 Koraku Bunkyo ku Tokyo 112...

Страница 2: ...10000...

Страница 3: ...t as this may cause the LM 092 to lose color or become deformed 4 To remove stains inside of the box wipe it using gauze soaked with water or neutral detergent diluted with water Do not use thinner be...

Страница 4: ...not be repaired The material used for molding in the manufacturing process may remain in the bronchial unit In this case massage the bronchus in which the material remains with fingers and rinse the m...

Страница 5: ...ntents 1 Outline and Features 2 Components and Configuration 3 Handling the Model 4 Cleaning and Maintenance Positioning with bronchial unit holders 5 Views of Bronchial Model 6 Storage Procedure 7 Sp...

Страница 6: ...sented bronchi include even quintenary bronchi e g B1ai A very thin bronchoscope can be inserted up to a quintenary bronchus The material is specialized silicone rubber The sense of bronchoscopy inser...

Страница 7: ...5 2 Components and Configuration Outer Box Cover for Outer Box Bronchoscope Inlet Stand Stand Bronchial Unit Holder Bronchial Unit...

Страница 8: ...side of the bronchial unit and spray the silicone until atomization from the peripheral ends of the bronchial unit can be confirmed It is difficult to spray the silicone into the upward peripheral por...

Страница 9: ...ow direction when it is open 3 3 The bronchial unit can be removed from the box Hold the bronchoscope inlet of the bronchial unit and push it into the inside of the box Now remove the bronchial unit t...

Страница 10: ...al unit it can be cleaned by the following procedure 4 1 Hold the bronchoscope inlet of the bronchial unit and push it into the inside of the outer box 4 2 Remove the bronchial unit together with the...

Страница 11: ...ronchial unit may break 4 5 Send water from the bronchoscope inlet and lightly massage the bronchial unit to clean its inside In massaging the bronchial unit never use your fingernails as this may res...

Страница 12: ...10 4 7 Attach the bronchial unit to the bronchial unit holders 4 8 Place the bronchial unit together with the stand in the outer box and pass the bronchoscope inlet through from the inside of the box...

Страница 13: ...11 Positioning with bronchial unit holders 10...

Страница 14: ...12 5 Views of Bronchial Model Assign bronchial numbers using these views FRONT...

Страница 15: ...13 BACK...

Страница 16: ...nit Product name 6 Storage Procedure 1 Sufficiently dry the bronchial unit residual rinsing water may cause mold growth 2 Check that the bronchial unit is attached to the specified bronchial unit hold...

Отзывы: