Handling and Safety Precautions

These precautions should be strictly observed to ensure safe, long-term use of 

the product.

Caring for the model after use

1.  After using this product, thoroughly flush out the lubricant with cold or hot water.
2. To clean the storage case, wipe with gauze or similar material moistened with water or a watered-

down,mild detergent.

 * Do NOT use thinner, benzine, or other solvents to clean the storage case.
3. Keeping this product in direct sunlight or exposed to UV light for a long period of time may cause it to 

deform or degrade. When not in use, keep it in the storage case in a flat area away from direct sunlight or 
UV light.

1. The contents of this instruction manual are subject to change without notice. 
2. This instruction manual may not be reproduced in part or in its entirety without permission. 
3. Please contact the manufacturer in the event that any errors or omissions are found in the contents of 
this instruction manual.
4. This product should be used only as described in this instruction manual. In particular, the product 
should not be used in any way that contravenes the precautions noted in the instruction manual.

Содержание Colonoscopy Lower GI Endoscopy Simulator Type II

Страница 1: ...olonoscopy Lower GI Endoscopy Simulator TypeII Please read this instruction manual carefully to ensure correct use of the product and store it in a safe place for easy access KOKEN CO LTD 1 4 14 Korak...

Страница 2: ...se permanent staining 6 When transporting this product in its storage case make sure the metal latches are closed Also if the storage case is tilted or experiences heavy shock the case or model may br...

Страница 3: ...generation of the polyp Be careful not to spill the storage liquid or throw it away before using all the Simulated Polyps for polypectomy 2 When resecting a Simulated Polyp for polypectomy always use...

Страница 4: ...exposed to UV light for a long period of time may cause it to deform or degrade When not in use keep it in the storage case in a flat area away from direct sunlight or UV light 1 The contents of this...

Страница 5: ...ng the Model 3 1 How to apply lubricant 3 2 How to assemble the intestine 3 3 How to attach simulated polyps for observation 3 4 How to attach an optional LM 103A Simulated Polyp for polypectomy 3 5 C...

Страница 6: ...bles actual biological material 2 Simulated polyps for observation can be attached to the ascending colon and descending colon for observational purposes 3 Laterally spreading tumors LST are replicate...

Страница 7: ...transparent cover 14 Screw for transverse colon 15 Storage case 5 2 Components and Configuration Name 1 Main unit 2 Rectum sigmoid colon part 3 Descending colon part 4 Transverse colon part 5 Ascendin...

Страница 8: ...fficult Use a lubricant specifically designed for endoscopes 3 1 How to apply lubricant Lubricant should be applied to the following four openings Applying lubricant 1 Remove the simulated peritoneal...

Страница 9: ...remove them from the main unit 7 2 Detach colon connectors from these three points 3 Pull the ascending and descending colons upward to remove them from the main unit 7 2 Detach colon connectors from...

Страница 10: ...ic flexure side connector Hepatic flexure side connector 8 4 Apply lubricant to the rectum sigmoid colon Insert lubricant from the anal region as well as the sigmoid colon connector opening After inse...

Страница 11: ...olon Transverse colon and descending colon Male Female 9 7 Apply lubricant to the ascending colon Squeeze lubricant into the intestine After inserting a generous amount squish the intestine together s...

Страница 12: ...he pin on the upper right section of the main unit then push holes in the descending colon s seat into the pins to attach the descending colon to the main unit 3 Align with the polyp attachment band P...

Страница 13: ...ing colon to the main unit Ascending colon and transverse colon Male Female 11 4 Reconnect the disassembled ascending colon to the transverse colon Make sure to align notch marks on each connector 5 A...

Страница 14: ...ng table to hold the model in place Absorption sheet Holding table Fixing pins 6 Attach the simulated peritoneal membrane sheet to the main unit Securing the model to the table Before using this model...

Страница 15: ...le lateral position 1 Align holes on the side of the main unit with the holding table s fixing pins 13 How to attach the model to the holding table dorsal position 1 Align holes on the bottom of the m...

Страница 16: ...1 Remove the polyp attachment band from the descending colon then insert the selected simulated polyp for observation into the polyp attachment hole Next re attach the polyp attachment band to cover t...

Страница 17: ...lyp attachment hole and re attach the ascending colon to the main unit 15 Attaching a simulated polyp to the ascending colon 1 Remove the ascending colon from the main unit insert the selected polyp f...

Страница 18: ...uction cable is included with this product Extra conduction cables are available as optional accessories if needed for the use of simulated polyps for polypectomies in both the ascending and descendin...

Страница 19: ...eturn electrode attach it so both surfaces are in contact with the plate 2 Attach a return electrode on hand to cover the conduction cable for simulated polyps for polypectomies When using a dual type...

Страница 20: ...ent hole then re attach the polyp attachment band to cover the flange 17 Attaching a simulated polyp for polypectomies to the descending colon 1 Remove the simulated peritoneal membrane sheet then rem...

Страница 21: ...etween the Velcro and re attach the simulated peritoneal membrane sheet Simulated polyp for polypectomies in set position Intestine Polyp attachment band Conduction cable ring Velcro 18 4 Position the...

Страница 22: ...nto the ascending colon s polyp attachment hole then re attach the ascending colon to the main unit 19 Attaching a simulated polyp for polypectomies to the ascending colon 1 Remove the simulated perit...

Страница 23: ...ween the Velcro and re attach the peritoneum sheet 20 4 Position the conduction cable between the Velcro and re attach the peritoneum sheet Simulated polyp for polypectomies in set position Main unit...

Страница 24: ...Transparent cover screws Transparent cover Transverse colon screw 21 3 5 Caring for the product after use Make sure to wash the Type II Colonoscopy Training Model after use as described below When wa...

Страница 25: ...lange plate from the rectum sigmoid colon 5 Use hot or cold water to rinse the lubricant out of each colon piece and all other parts removed Wipe any remaining moisture from the parts then place them...

Страница 26: ...x 5 kg 4 Specifications Product name Product No 1 Small intestine for Colonoscopy semi difficult type LM 107A 2 Small intestine for Colonoscopy easy type LM 107B 3 Ascending Colon for Colonoscopy LM 1...

Отзывы: