KOHTECT 107VF Скачать руководство пользователя страница 3

General 

Safety Precautions 

To prevent possible electrical shock, fire, personal injury or the device 
damage: 

• Carefully read user’s manual

• Do not 

place sensor on the objects which exposed to high voltages. 

These voltages could cause personal injury or death. 

• 

The  Analyzer  could  not  be  used  in  potentially  explosive 

environments. 

•  Take  measures  to  prevent  cables  and  straps  become  entangled  by 

rotating part of machines at measurement site. 

•  Do 

not  expose  107VF  parts  to  heavy  impacts,  high  humidity  and 

extreme temperature. 

• Do not try

 to open the display unit 

 this can damage the system, and 

your after-sales service warranty will come void 

 

 

 

 

 

 

 

 

 

Содержание 107VF

Страница 1: ...107VF Vibration Analyzer User s Manual 2018...

Страница 2: ...asurement functions 6 Operation 6 Keyboard 6 Settings 7 Date Time 7 Sensors 8 Units 8 Auto OFF 8 Vibration 9 Vibration measurement settings 10 Taking measurements 11 To save measurements 12 Route base...

Страница 3: ...s could cause personal injury or death The Analyzer could not be used in potentially explosive environments Take measures to prevent cables and straps become entangled by rotating part of machines at...

Страница 4: ...email makes it ideal for data collection at remote sites Simple in use with free firmware upgrades comes with data management and reporting software Kit Content The 107VF kit includes 107VF display un...

Страница 5: ...cy 0 5 0 60 C 1 40 120 C 2 70 180 C 4 70 380 C Tachometer measurement range 10 200 000 rpm Accuracy 0 1 and 1rpm FFT spectrum resolution 400 800 1600 lines Data storage 4GB micro SD card PC interface...

Страница 6: ...s speed of rotation by means of contactless optical sensor The measurement result is displayed in RPM and Hz IR thermometer contactless measurement of object temperature The measurement result is disp...

Страница 7: ...to OFF delay setup Date Time Use arrow keys to set date Hold then press or for month decrement increment Confirm by when correct date is set Use keys to set minutes and hours Use key to switch focused...

Страница 8: ...or charge type sensors to choose from Confirm choice by key Type S N and Sensitivity fields are editable Use key to choose field to edit Then use arrow keys to edit the field value Units This option i...

Страница 9: ...measures vibration Acceleration Velocity and Displacement In ISO 10816 mode measurement result is compared to the built in table of vibration severity grades according to ISO 10816 3 Use keys to choos...

Страница 10: ...per frequency limit Can be set from 200 to 10000 Hz for Acceleration from 200 to 5000 Hz for Velocity from 200 to 800 Hz for Displacement FFT lines FFT spectrum resolution Can be set to 400 800 1600 l...

Страница 11: ...running Use key to toggle FFT spectrum waveform display Press key to stop resume measurement When measurement is stopped Press key for Options Save to save measurement data Press key to proceed Forma...

Страница 12: ...en press key save measurement Device writes two files at a time FFT spectrum file and waveform file Device remembers path to the last written files To create new folder press key Date time stamp is us...

Страница 13: ...and download it to the device Go to Documents menu move cursor to the route file and press key Use to browse route points Attach sensor at the measurement point and press key Device takes measurement...

Страница 14: ...2 only Connect optical probe to the device Enter Tachometer menu Aim optical probe to the rotating machine part with attached reflective tape Press key to start stop measurement Device displays measur...

Страница 15: ...Thermometer 107VF T2 only Connect optical probe to the device Enter Thermometer menu Aim optical probe to the machine Press key to start stop measurement Device displays measurement result in C and F...

Страница 16: ...NPP KOHTECT 73 V Lomonosova str of 38 Kiev 03189 Fax 38044 2577338 www koh tect com...

Отзывы: