background image

Product Information

Applicable product:
Drop-in rim style

K-1114-G

shown

Drop-in, 4-side integral flange

K-1114-GF

not shown

Fixture*:
Bathing well
Basin area

bottom

55

(139.7 cm) x 23-1/4

(59.1 cm)

Basin area top

64

(162.6 cm) x 32

(81.3 cm)

Weight

132 lbs (60 kg)

To overflow
Water depth

15

(38.1 cm)

Capacity

78.5 gal (297 L)

* Approximate measurements for comparison only.

Drop-in cutout dimensions:
70-1/2

(179.1 cm) x 40-1/2

(102.9 cm)

Blower motor:

Heater

V

Hz

A

1 hp

300 W

120

60

5

Minimum access panel pump/control:
20

(50.8 cm) W x 15

(38.1 cm) H

required

Required Electrical Service

Dedicated circuit required, protected with a Class A

Ground-Fault Circuit-Interrupter (GFCI):
Pump/control

120 V, 5 A, 60 Hz

Blower motor is supplied with a 24

(61 cm) grounding-type

plug-in cord.

Notes

Install this product according to the installation guide.
Floor support under this product must provide for a minimum of

39 lbs/square foot (190 kg/square meter) loading.
If installing a rim-mount faucet, make sure there is no interference

with the drain overflow and circulating system before drilling any

holes. Consult local and national codes for minimum air gap

requirements if installing a spout on the faucet deck.
The hot water supply should be 70% of the capacity of the bath or

greater. Installations will vary.
This fixture conforms to ANSI Standard Z124.1.2. All dimensions

are nominal.

72" (182.9 cm)

42" (106.7 cm)

1-1/2" OD

21" 
(53.3 cm)

3-1/2" 
(8.9 cm)

2-7/8" (7.3 cm)

3" (7.6 cm)

Recommended faucet area

No change in measurements if connected with 
drain illustrated. (K-11677 or K-11677M)

19-1/2" 
(49.5 cm)

1-1/2" 
(3.8 cm)

Drop-In Rim 

Detail

1-1/4" 
(3.2 cm)

Tile Flange 

Detail

1-1/2" 
(3.8 cm)

11-1/16" (28.1 cm)

3-3/4" 
(9.5 cm)

1" (2.5 cm) from 
the Floor to the 
Bottom of the Drain

Blower/Control Access 
20" (50.8 cm) W x 
15" (38.1 cm) H Min

1076052-1-A

2

Kohler Co.

Содержание Windward BubbleMassage K-1114-G

Страница 1: ...are for Mexico i e K 12345M Los números de productos seguidos de M corresponden a México Ej K 12345M Français page 3 Español página 4 USA 1 800 4 KOHLER Canada 1 800 964 5590 México 001 877 680 1310 kohler com K 1114 G K 1114 GF 1076052 1 A 2007 Kohler Co ...

Страница 2: ...o the installation guide Floor support under this product must provide for a minimum of 39 lbs square foot 190 kg square meter loading If installing a rim mount faucet make sure there is no interference with the drain overflow and circulating system before drilling any holes Consult local and national codes for minimum air gap requirements if installing a spout on the faucet deck The hot water sup...

Страница 3: ...oduit selon le guide d installation Le support du sol sous ce produit doit pouvoir soutenir une charge minimale de 39 lbs pied carré 190 Kg m2 Si un robinet sur rebord est installé s assurer qu il n y ait pas d interférence avec le trop plein du drain et le système de circulation avant de percer tout orifice Consulter les codes nationaux et locaux pour les exigences d espace d air minimum lors de ...

Страница 4: ...rme a la guía de instalación El soporte del piso debajo de este producto debe poder soportar una carga mínima de 39 lbs pie cuadrado 190 kg metro cuadrado En caso de instalar la grifería en el borde asegúrese de que no interfiera con el rebosadero de desagüe y el sistema de circulación antes de taladrar los orificios Consulte los códigos locales y nacionales para obtener los requisitos mínimos de ...

Отзывы: