SYMPTOMS

A. Adjust flapper chain assembly for proper slack.

B. Inspect, clean and, if necessary, replace

flapper ball and/or seat.

PROBABLE CAUSES

CORRECTIVE ACTION

1. Fill valve turns on/off by

itself without toilet being
flushed.

A. No slack in flapper chain assembly, holding

flapper off seat.

B. Flush valve flapper ball worn, dirty or

misaligned with flush valve seat; or seat
corroded so flapper will not seal.

A. During fill cycle, hold float under water a few

seconds to allow it to fill with water ballast.

B. Adjust the cross-shaped thread on float rod

until water level is at marked water line.

A. Valve float cup does not contain enough water

to provide required ballast.

B. Float height incorrect.

4. Long or noisy tank fill

cycle.

A. Perform Corrective Action 2.A.

A. Plugged valve inlet or supply line.

A. Adjust tank water level.
B. Unclog trapway; clean rim holes.
C. Clear obstruction from soil pipe or vent.
D. Open supply shut-off valve.

A. Water level is too low.
B. Trapway or rim holes are obstructed.
C. Soil pipe or vent is obstructed.
D. Supply shut-off valve not fully open.

5. Poor flush.

A. Toilet trapway is obstructed.
B. Soil pipe or vent is obstructed.

A. Use plunger to unclog.
B. Clear obstruction from soil pipe or vent pipe.

6. Toilet overflows.

2. Fill valve continues to

run, allowing water to
enter tank.

3. Incorrect water level

height.

A. Foreign particles lodged under the float valve

seal (located under fill valve cap).

B. Fill valve seal (located under float valve cap)

may be cracked or split.

C. Tank water level set above overflow level.

D. Water leaking past flush ball.
E. Trip lever binding, holding flush ball open.

A. Shut off water supply; remove fill valve cap

assembly by rotating 1/8 turn counterclockwise.
Cover uncapped lower valve unit with an
inverted cup (holding it to prevent overspray),
and turn water on and off a few times. Clean
fill valve seal surface (located under float valve
cap). Replace fill valve cap assembly by
engaging lugs and rotating 1/8 turn clockwise.
Turn water on. Install filter in supply line to
prevent recurring problems.

B. Replace seal.

C. During fill cycle, hold float under water a few

seconds to allow it to fill with water ballast.
Adjust float by adjust the cross-shaped thread
on float rod and sliding float up or down on
float rod until water level is at marked water
line.

D. Replace flush ball.
E. Turn trip lever nut clockwise to loosen until trip

lever no longer binds.

-6-

FILL FLOAT WITH
BALLAST

Adjust the float by the cross-shaped
thread and sliding it up or down on the
float rod until the water level is at the
marked water line.

Test flush the toilet.

Check all connections for leakage for
several days.

Set the tank cover in place on the tank.

Fig.#14

14

1355511-T01-A

Содержание VEIL K-1666T-S

Страница 1: ... K 1660T Includes Tank K 1664T SLT3 VEIL Class Five 2PC Toilet 400mm K 1667T SL Includes Bowl K 2597T Includes Tank K 1664T SLT4 Includes K 4141T Includes K 4141T Includes Elongated Slim Seat K 77070T Includes Elongated Slim Seat K 77070T Quiet Close Quiet Close 305mm K 1666T S K 1660T K 1664T ST3 400mm K 1667T S K 2597T K 1664T ST4 305mm K 1666T SL K 1660T K 1664T SLT3 400mm K 1667T SL K 2597T K ...

Страница 2: ... 254mm 305mm 8mm T 2 Carefully inspect the new fixture for any sign of Damage For new construction refer to the dimensions in and for locating the shut off valve The fill valve nut has been factory tightened to design specifications If re tightening is required wrench tighten 1 4 turn past finger tight Fig 1 Fig 3 WARNING Risk of external leakage Fixture dimensions are nominal and conform to toler...

Страница 3: ...k or cause damage Kohler is not responsible for any damage caused by installation with the use of cement mm 67mm 200mm 190 Fig 3 3 Fig 4 4 Fig 5 5 TO INSTALL SUPPLY SHUT OFF VALVE Install the supply shut off valve so it is 200mm above the finished floor line and 190mm to the left of the closet flange centerline The centerline of the supply shut off valve outlet should extend 67mm from the finished...

Страница 4: ...1 2 o C Fig 6 6 Install brackets Plastic Trap Outlet Toilet Gasket Fig 8 8 Fig 9 9 Fig 10 10 Install plastic to ground and mounted with 3 set of bolts not supplied firmly Carefully align and lower the bowl Apply weight to the bowl rim to let the outlet insert into plastic trap Carefully thread the screws into the brackets until toilet is secure Alternately tighten left and right sides to prevent p...

Страница 5: ...ater supply off Replace END by engaging lugs and rotating 1 8 turn clockwise Turn on water supply Check that water level is at the marked water line 1 8 1 8 TO CONNECT WATER SUPPLY Flexible hose not provided are recommended to connect the supply line to the fill valve If you use a rigid connection not provided take care not to apply side forces to the bottom of the fill valve Be sure the rigid con...

Страница 6: ...e continues to run allowing water to enter tank 3 Incorrect water level height A Foreign particles lodged under the float valve seal located under fill valve cap B Fill valve seal located under float valve cap may be cracked or split C Tank water level set above overflow level D Water leaking past flush ball E Trip lever binding holding flush ball open A Shut off water supply remove fill valve cap...

Страница 7: ...1 A B A B A B C D E A 1 8 1 8 B C D E 2 3 A B A B 4 A 2A A 5 A B C D A B C D 6 A B A B 7 1355511 T01 A ...

Страница 8: ... cleaners or solvents Do not use in tank cleaners Products containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage 0 C o ...

Отзывы: