Install the Showerhead

Before installation, install the restrictors if needed. Install the 

restrictors into the connectors on the showerhead(33).
Remove the protector caps from the shower arm outlet(34) and 

showerhead. 

Insert the showerhead to the shower arm outlet 

as shown. 

Insert the pin(35) into the slot. Tighten the screw(36) with 2.5mm 

hex wrench(27).  

WARNING: 

Ensure the screw is tightened to avoid the product 

falling and personal injury.

10

8

9

25
26
24

23

23

21

21

29

29

27

28

27

30

31

31

32

28

30

11

12

91º

17

18

8

Slot

Protector cap

Restrictor

33

35
27

36

34

13

14

21

21

14

7

22

14

Protector cap

37

39

41

40

38

17

18

8

19

20

The finished wall

8

6

14

7

13

(Not provided)

14

15

16

6

7

6

5

18

Hot

Cold

   

                                                                         

1418848-2A-C          

                                                                                                                                          5 

  

   

                                                                          

1418848-2A-C           

                                                                                                                                         4

 

Install the Faucet Body

Cut off the protectors(6) beyond the wall after the wall is finished. As figure 

8

 shown, uninstall and discard the plugs(14) 

from the connections(21) with 8mm hex wrench(13, not provided). Remove the screws(22) from the protector(7) with 

screwdriver(not provided) and pull it out. Check whether the O-rings on the connections(21) and showerhead tubes(23) 

are intact. 

As figure 

9

 shown, adjust two screws(25) with 3mm hex wrench(24). Install the faucet body to the connections(21) and 

showerhead tubes(23) until it is against the finished wall. Tighten two screws(25) with 3mm hex wrench. Press the 

plugs(26) into the faucet.

Water Pressure Test

As figure 

5

 shown, uninstall the protectors(6) with screwdriver(not provided). Remove the plugs(14) with 8mm hex wrench 

(13, not provided). Flush water supply pipes for about one minute to remove any debris. Reinstall the plugs. Remove the 

protector cap(15) from the protector(7), and connect the connection(16) with one waterpipe(not provided). 

As figure 

6

 shown, remove the screws(17) from the protector(8) with screwdriver(not provided) and pull it out. Remove the 

connectors(18) with 8mm hex wrench, take off the filter washers(19). Flush water supply pipes for about one minute to 

remove any debris. Insert two G1/

 plugs(not provided) into the connections(20). 

Apply water pressure(8bar) test on the product. Check for leaks. Turn off the water supplies. 

Remove two G1/

 plugs from the connections(20). Reinstall the filter washers(19) and connectors(18). Remove the 

waterpipe from the connection(16). Reinstall the protector cap(15) and protectors(6, 8).

As figure 

7

 shown, ensure the out surface of the finished wall is between the MAX and MIN marks on the protectors(6, 8).

Install the Shower Arm

As figure 

10

 shown, when the finished wall is completed, remove the screws(17) from the protector(8) with screwdriver 

(not provided) and pull it out. The angle between connectors(18) and finished wall should be 91 degrees. 
As figure 

11

 shown, loosen the screws(28, 29) with 2.5mm hex wrench(27). Slide the escutcheon(30) onto the shower 

arm(31). Install the shower arm with escutcheon onto the connectors(18), tighten the screws(29) with 2.5mm hex wrench 

to secure the shower arm. Remain the protector cap(32) on the shower arm before the showerhead is installed.
As figure 

12

 shown, apply a ring of plumbers putty around the back surface of the escutcheon(30). Push the escutcheon 

until it is against the wall. Tighten the screw(28) into the bottom of the escutcheon with 2.5mm hex wrench. Remove any 

excess putty.

Install the Handshower 

Remove the protector cap from the connector(37)

Put the screen washer(38) into the shower hose(39). 

Connect the handshower(40) and connector(37) 

with shower hose. Tighten all the connectors. 

NOTE

: Don’t over tighten.

Install the check valve(41) into the handshower if 

needed. 

13

(Not provided)

The finished wall

Содержание URBANITY 25717T-9

Страница 1: ...way from heater or it may become damaged and cause injury to the user OPERATION CONDITION 25717T 9 Recessed Thermostatic Dual Shower Faucet Multifunction Showerhead The temperature is set by slowly turning the temperature handle right hand handle For safety reasons there is a stop that limits temperature to 37ºC To get a higher temperature push the button on right handle and continue turning the t...

Страница 2: ...apter spline align with the indicator line on the stopper Tighten the screw 52 with a screwdriver Install the temperature handle 49 Ensure the number 37 on temperature handle is upward vertically After assembly it could not be turned counter clockwise if not pushing the button Tighten the screw 50 with 2 5mm hex wrench 27 Insert the plug 51 Clear the Thermostatic Cartridge Very hard water can obst...

Страница 3: ... spline 53 Under the normal condition of water flow slowly turn the temperature selector Always in the same direction from the cold water position until water temperature reaches 37ºC If the temperature goes over 37ºC go back to the cold setting and reset it When the temperature is stable do not turn the cartridge spindle Install the adapter spline Ensure the indicator line on the adapter spline a...

Страница 4: ... with one waterpipe not provided As figure 6 shown remove the screws 17 from the protector 8 with screwdriver not provided and pull it out Remove the connectors 18 with 8mm hex wrench take off the filter washers 19 Flush water supply pipes for about one minute to remove any debris Insert two G1 2 plugs not provided into the connections 20 Apply water pressure 8bar test on the product Check for lea...

Отзывы: