background image

   

                                                                         

1387023-2A-A          

                                                                                                                                          5   

  

   

                                                                          

1387023-2A-A           

                                                                                                                                         4 

  

Install the Body

To perform installation, installer must provide G1/2

″ 

female supply 

fittings(1), spaced 150mm apart, horizontally and vertically to the 

finished flat wall. Flush the water supply pipes thoroughly to 

remove any debris.

NOTE: 

Apply water pressure test on water supply pipes before 

installing the connectors(2).

Apply enough tape or suitable sealant on threads of connectors. 

Install two connectors into the hot and cold supply pipes. 

Adjust the center-to-center distance between the connectors to 

150mm horizontally. They should extend 36~45mm beyond the 

finished wall. 

NOTE

: Rotate the C-rings with their openings 

downward, and pull forward the C-rings to clamp the connectors.

Adjust two screws(4) with 3mm hex wrench(3). Install the faucet 

body to the connectors until it is against the finished wall. Ensure 

the upper surface is horizontal with the level(5).

Tighten two screws with 3mm hex wrench(The screws should 

contact with the connectors through the C-rings’ openings). 

Press the plugs(6) into the faucet.

Cold

Hot

1

2

150mm

5

36~45mm

4

3

6

Cold

Hot

Opening 

downward

Screw

C-ring

Drain notch

12

13

14

15

17

18

16

INSTALLATION

Install the Bracket

Determine a suitable location on the finished wall to install bracket. 

Ensure it should avoid buried cables and pipes in the wall.
Mark the mounting holes of the base(12) on the wall according to 

the dimension. Drill two holes in the finished wall, the holes should 

match the anchors(13) and be vertical. Install the anchors. Tighten 

the screws(14) to fix the base on the finished wall. 

NOTE:

 The 

direction of the base is shown in the figure. 
Loosen the screw(17) in the bracket(16) bottom with hex wrench 

(15) until the bracket can be installed into the base. Slide the 

escutcheon(18) onto the bracket. Apply a ring of plumbers putty or 

other sealants around the underside of the escutcheon. Move the 

bracket onto the base until it is against the finished wall and 

confirm the drain notch and screw hole are pointed down. Tighten 

the screw(17) with hex wrench to fix the bracket and escutcheon 

on the finished wall. Remove any excess putty or sealant.

Clear the Filter

The filters protecting the faucet device may get obstructed and 

reduce water flow. When this happens, turn off the water supply, 

uninstall the shower column.
Take out the plugs(6). Unscrew two screws(4) with 3mm hex 

wrench(3) to uninstall faucet. Take out the filters by hand. Clean 

the filters by soaking them in warm vinegar. Reinstall in turn. 

CARE AND MAINTENANCE

INSTALLATION CHECKOUT

Ensure that all connections are tight, the switch buttons are not 

turned on. Turn on the water supply. Run water through the valve. 

Check for leakage. Repair as needed.
Press the buttons separately. Check whether all connections and 

water flow are well.

 

Shut off the faucet. 

Verification and Setting

Make sure that the water feeds of the faucet have reach their 

highest temperature by letting the water run sufficiently. When the 

number 37 on the temperature handle(19) is upward vertically, 

the temperature of the water coming out of the faucet must be 

within a range of 36ºC and 38ºC, as measured by a thermometer. 

If this is not the case, the installer can adjust the setting. Proceed 

with the setting as follows: 
Remove the plug(21). Take out the screw(20) with 2.5mm hex 

wrench(22) to uninstall the temperature handle(19). Remove the 

screw(23) with a screwdriver. Remove the adapter spline(24). 
With the faucet on “cold” normal water flow, slowly turn the 

temperature selector(Always in the same direction) until water is 

at 37ºC. If the temperature goes over 37ºC, go back to the “cold” 

setting and set again. When the temperature is stabilized, do not 

turn the cartridge spindle. Install the adapter spline. Ensure the 

indicator line on the adapter

 

spline align with

 

the indicator line on 

the stopper. Tighten the screw(23) with a screwdriver. Install the 

temperature handle. Ensure the number 37 on the temperature 

handle is upward vertically(After assembly, it could not be turned 

counter-clockwise if not pushing the button). Tighten the screw

(20) with 2.5mm hex wrench. Insert the plug(21).

Number 37

22

19

20

21

23

24

Upward 

horizontally

Spindle

Indicator line

4
3

6

Filter

Install the Handshower 

Remove the protector cap from the connector(7)

Put the screen washer(8) into the shower hose(9). Connect the 

handshower(10) and connector(7) with shower hose. Tighten all 

the connectors. 

NOTE

: Don’t over tighten.

Install the check valve(11) into the handshower if needed. 

7

9

11

10

8

Protector cap