background image

Underscore

®

 Cube

48" x 48" Heated BubbleMassage

 air bath w/ whirlpool

K-1969-XHGH

24"
(610 mm)

1"
(25 mm)

No change in measurements if connected
with drain illustrated. (K-8150)

Drop-in Rim

Detail

Lumbar
Angle 5°

Blower Motor/Control Access
34" (864 mm) W x 15" (381 mm) H

24" (610 mm)

1"
(25 mm)

34"
(864 mm)

3"
(76 mm)

48" (1219 mm)

29"
(737 mm)

3-1/8"
(79 mm)

2-15/16"
(75 mm)

1-1/2" Bath Drain

7-7/8"
(200 mm)

1-1/2"
(38 mm)

Required Electrical Service

Three dedicated circuits required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI). Outside North America,
this device may be known as a Residual Current Device (RCD).

Blower:

120 V, 15 A, 60 Hz

Air bath, Pump:

120 V, 15 A, 60 Hz

Heater:

120 V, 15 A, 60 Hz

Technical Information

All product dimensions are nominal.

Installation:

Drop-in, Undermount

Drain location:

Center

Basin area, bottom:

39-3/8" x 39-3/8" (1000 mm x 1000 mm)

Basin area, top:

44-5/8" x 44-5/8" (1133 mm x 1133 mm)

Weight:

218 lbs (98.9 kg)

Minimum floor load:

102.3 lbs/ft² (499.5 kg/m²)

Water depth:

27-1/2" (699 mm)

Water capacity:

171 gal (647.3 L)

Template:

K-578, not required, not included

Electrical component

rating:

Blower: 120 V, 10 A, 60 Hz
Air bath: 120 V, 5 A, 60 Hz
Pump: 120 V, 7 A, 60 Hz
Heater: 120 V, 12 A, 60 Hz

Blower speed:

Variable

Notes

Measure your actual product for rough-in
details.

Install this product according to the installation
instructions.

The hot water supply should be 70% of the
capacity of the bath or greater. Installations will
vary.

1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to 

www.kohler.com

.

12-1-2021 04:35 - US/CA
 