INSTALLATION
How to Install the Faucet
To perform installation, installer must provide G1/2
˝
female supply
fittings(1), spaced 150mm apart and horizontal. The supply fittings should
be vertical and not beyond the finished wall. Hot supply pipe must be
located on the left.
Install the two offset connectors(2) into the hot and cold supply pipes.
Use appropriate thread sealants or thread tape on pipe threads.
Adjust the center-to-center distance between the connectors to 150mm
and horizontal. They should extend 36 to 47mm beyond the finished wall.
Slide the escutcheons(3) onto the nuts(4). Put the washers(5) into the
nuts, thread the nuts to connectors. Tighten the nuts with strap wrench or
soft cloth between product and regular wrench. Push the escutcheon
against the finished wall.
Install the restrictor(10) into the handshower(9) inlet if needed.Connect
hose(6) to the faucet outlet(8), and to the handshower with washers(7).
INSTALLATION CHECKOUT
CLEANING INSTRUCTIONS
All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft
cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc. which could adversely
affect the finish and are not recommended for cleaning.
Do not use abrasive cleaners or solvents on Kohler faucets and fittings.
How to Install the Bracket
Determine a suitable location on the finished wall to install the bracket.
Mark bracket base mounting hole locations on the wall according to the
dimension. Drill two holes on the finished wall, the holes should match
the anchors(11). Install the anchors. Tighten screws(12) to secure
bracket base(13) to the finished wall. Put the bracket(14) onto the bracket
base and lock by stopper. Hang the handshower on the shower bracket.
How to Operate the Handshower
Press the buttons of the handshower to change the water flow.
How to Maintain the Handshower
Any debris or mineral build-up may cause the flow stream to become
distorted or reduce the flow rate. To remove the debris or mineral build-up,
run water through the handshower, firmly press or rub your finger back
and forth across the rubber nozzles.
Remove and clean the screen washer.
Katalyst Air
Intense Massage
2
1
Hot
Cold
150mm
36-47mm
Hot
Cold
3
4
5
6
7
8
9
10
22.5mm
11
12
14
13
9
15
9
16
Ensure that all connections are tight. Ensure that the handle is in the off
position.
Turn on the drain and main water supply, and check for leaks. Repair as
needed.
For 8963T-B9
Bath & Shower Faucet
Remove the handshower(9). Press the bulge(15) of the aerator(16) on
the underside of the spout, Remove the aerator. Turn on the faucet. Run
the water through the spout about one minute to remove any debris.
Check for leaks. Remove any debris from the aerator. Shut off the faucet.
Reinstall the handshower and aerator.
For 8962T-B9
Shower Faucet
Remove the handshower(9). Turn on the faucet. Run the water through
the spout about one minute to remove any debris. Check for leaks. Shut
off the faucet. Reinstall the handshower.