No change in measurements if connected with drain illustrated. (K-37386)

Recommended Faucet Hole Location

4"
(102 mm)

4"
(102 mm)

Recommended Faucet Location

Lumbar
Angle 19°

30-5/16" (770 mm)

18-1/4"
(464 mm)

25-5/8"
(651 mm)

3-3/8"
(86 mm)

34-11/16" (881 mm)

4"
(102 mm)

26-1/2"
(673 mm)

60-9/16" (1538 mm)

17-5/8"
(448 mm)

14-1/4" (362 mm)

45-13/16" (1164 mm)

5-3/4"
(146 mm)

3/4"
(19 mm)

8-3/8"
(213 mm)

2-3/4"
(70 mm)

Notes

Required Electrical Service

Measure your actual product for rough-in details.

Two dedicated circuits required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI). Outside North America,
this device may be known as a Residual Current Device (RCD).

Install this product according to the installation
instructions.

The hot water supply should be 70% of the
capacity of the bath or greater. Installations will
vary.

120 V, 15 A, 60 Hz

Blower:

120 V, 15 A, 60 Hz

Heater:

Technical Information

If installing a rim-mount faucet, make sure there
is no interference above or below the deck before
drilling any holes.

All product dimensions are nominal.

Freestanding

Installation:

Center

Drain location:

39-5/8" x 23-5/8" (1006 mm x 599 mm)

Basin area, bottom:

49-9/16" x 25-1/2" (1259 mm x 648 mm)

Basin area, top:

170 lbs (77.1 kg)

Weight:

50 lbs/ft² (244.1 kg/m²)

Minimum floor load:

16" (406 mm)

Water depth:

60 gal (227.1 L)

Water capacity:

Footprint, 1364288, not required, not
included

Template:

Blower: 120 V, 10 A, 50 Hz
Heater: 120 V, 5 A, 60 Hz

Electrical component

rating:

1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to 

www.kohler.com

.

1-6-2020 05:50 - US/CA

Sunstruck

®

freestanding Heated BubbleMassage

 air bath

K-24009-GH