![Kohler STRUKTURA K-5888T Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/kohler/struktura-k-5888t/struktura-k-5888t_installation-instructions-manual_1990148010.webp)
1237458-T01-A
Manual Flushing
Sensorless Cleaning Mode
Press the manual button for about 1 second and the urinal will
automatically flush once.
Enter the sensorless cleaning mode by pressing the manual
button for about 3 seconds after the flushing is finished. The
controller will ring twice every 2 seconds.
Under this mode, press the manual button for about 1 second to
start or stop flushing. The longest continuous flushing time is
about 15 seconds.
The urinal will automatically exit this mode after it started for
about 8 seconds. You can also exit this mode by pressing the
manual button for about 5 seconds. The controller stops ringing
after the urinal exiting this mode.
This function can be used after the power is
turned on for ten minutes.
2
Notice:
Manual Button
Fig.22
22
-10-
MAINTENANCE
Fig.23
23
Clean the Filter Screen
If the flushing volume reclines sharply after installation or
used for a long time with no cause from water pressure, the
filter may need a wash. Please operate as following steps:
Remove the
a. Turn off the water supply and power
supply before cleaning the filter.
b. Avoid damaging or losing the filter during
cleaning.
Caution:
Fixture, Valve, Battery Box Assembly and take
out the filter, clean the filter and then reinstall it.
Filter
Valve Cap Kit
Fixture, Valve,
Battery Box Assy.
a.
b.