11. Secure the Bath – Drop-In
Verify that the studs are within 1/8
″
(3 mm) of the bath at the recommended support clip or screw
locations. Shim if necessary.
Position the bottom lip of the attachment clip under the edge of the bath and place the tab against
the bath flange.
Drill pilot holes through the flange at the attachment clip locations to protect the flange from
cracking when the fasteners are installed.
Slide the attachment clip into place between the center of the stud and the bath.
Secure the attachment clips with galvanized or plated non-tapered flathead screws.
5-1/4" (133 mm) for series 7726, 7727 and 7728
5-15/16" (135 mm) for series 7730 and 7731
Attachment Clip
Screw
Attachment Clip
Flange
Flange
3/4" (19 mm) Plywood
Section at Drain End
Ø 2" (51 mm)
Drain
18-3/4"
(476 mm)
17"
(432 mm)
Ø 2-1/2" (64 mm) Overflow
16-1/2" (419 mm)
13/16" (21 mm)
1139487-2-H
16