1265596-2A-A
2
1265596-2A-A
3
INSTALLATION
1. How to Install the Faucet
To perform installation, installer must provide G1/2
˝
female supply fittings(1), spaced 150mm apart and horizontally. The supply
fittings should be vertical and not beyond the finished wall. Hot supply pipe must be located on the left.
Flush the water supply pipes thoroughly to remove debris. Install the two offset connectors(2) into the hot and cold supply pipes.
Use appropriate thread sealants or thread tape on pipe threads.
Adjust the center-to-center distance between the connectors to 150mm and horizontally. They should extend 40~45mm beyond
the finished wall. Thread the escutcheons(3) onto the connectors until they are against the finished wall. Put the washers(4) into
the nuts(5), thread the nuts to connectors. Tighten the nuts with strap wrench or soft cloth between product and regular wrench.
CLEANING INSTRUCTIONS
All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft cloth. Many
cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc. which could adversely affect the finish and are
not recommended for cleaning.
Do not use abrasive cleaners or solvents on Kohler faucets and fittings.
2. How to Install the Shower Column
Select a location in vertical wall to install shower column according
to rough-in dimensions.
Drill the lower hole as anchors(6) diameter and lower base(8-1)
position in the finished wall (
NOTE:
The arrow in the base is
upward). Press anchors into the hole, secure the base by the
screws(7).
Rehearse the slide bar kit(9) installation for the upper base(8-2)
mounting location determination. Slide the tube joint(10) onto the
slide bar kit, and connect them to the base(
NOTE:
The arrow in
the base is up). Install the screws(12) into the tube joint with the
hex wrench(11), and tighten them.
Place the slide bar and the body
against the finished wall. Connect
the lower base and the diverter body
kit(13). Position and tighten them by
hex wrench. Mark the hole of upper
base(8-2) with a pencil. Uninstall the
slide bar kit and tube joint.
(
NOTE:
Don’t lose the screws.)
Drill holes on the mark. Press the
anchors into the holes. Secure the
upper base(8-2) by the screws.
Install the tube joint(10) to the base
(8-2) and tighten them by screws.
Reinstall the slide bar kit with
escutcheons(14) to the bases.
Tighten the screws with the hex
wrench. Screw the escutcheons with
the bases until against the finished wall.
Install the tube kit(15) into the slide
bar kit. Install the nut(16) onto the
tube kit with soft cloth between
internal hole of the nut and the tube
kit. Then screw the nut onto the slide
bar kit with strap wrench or soft cloth
between the nut and regular wrench.
6
7
12
8-2
14
6
7
12
8-1
14
13
16
15
10
11
9
3. How to Install the Handspray & Hose
Remove the guards on the outlet connectors of 500mm
length hose(18). Connect the outlet(17) to the connector
(19) with the hose(18), and tighten.
Turn the diverter handle(20), run hot and cold water for
about one minute to remove any debris.
Remove the guards on the outlet connectors of 1500mm
length hose(21). Tighten one connector(21-1) of the hose
(21) to the connector(22). Put the check valve(23) into the
handspray(24) inlet if needed. Remove the washer from
another connector(21-2), replace with the washer(25).
Tighten the handspray to the connector(21-2) of the hose.
Ensure that all connections are tight. Ensure that the handles are in the off position. Turn on the
drain and main water supply, and check for leaks. Repair as needed.
Remove the aerator(30) with the key(29) provided. Run hot and cold water through spout about
one minute to remove any debris. Clean the aerator assembly. Shut off the faucet. Reinstall the
aerator assembly.
INSTALLATION CHECKOUT
4. How to Install the Showerhead
Turn the diverter handle(20), run hot
and cold water for about one minute to
remove any debris before the shower
head(26) is installed.
Take out the washer(28) and install the
restrictor(27) into the showerhead as
shown if needed, reinstall the washer.
Tighten the showerhead onto the tube
kit outlet with strap wrench.
OPERATION INSTRUCTIONS
CARE AND MAINTENANCE
1
Hot
Cold
150mm
3
2
150mm
40~45mm
5
4
29
30
Verification and Setting
Make sure that the water feeds of the faucet have reach their highest temperature by letting the
water run sufficiently. With the selector in position 37ºC, the temperature of the water coming out
of the faucet must be within a range of 36ºC and 38ºC, as measured by a thermometer. If this is
not the case, the installer can adjust the setting. Proceed with the setting as follows: Uninstall
handle kit. With the faucet on “cold” normal water flow, slowly turn the temperature selector
(always in the same direction) until water at 37ºC is obtained. If the temperature goes over 38ºC,
go back to the “cold” setting and set again. When the temperature is stabilized, without turning
the cartridge spindle, make sure the reference number 37 mark on the temperature handle aligned
with the round laser mark on the body. Tighten the screw with the screwdriver, put on the plug.
Spindle
Round
laser mark
Number 37
33
34
35
32
31
Stop assy
Cartridge
Cartridge
Fig.1
Fig.2
Stop pin
Stop pin
Notch
Notch
Fig.3
Fig.4
Groove
Round mark
Fig.5
Fig.6
After cleaning, install the “stop assy” back
on the cartridge, adjusting the stop pin into
the notch(Fig.4). Install the assy cartridge
and stop in the body, adjusting the stop pin
into the notch(Fig.5).
NOTE:
Do not turn the
cartridge when reinstall it. If you turned it
without carefully, you should adjust it and
be sure that the round mark is correctly in
line with the groove(Fig.6), or readjust as
per the steps of verification and setting.
Install the temperature selector(without
turning the spindle). Align the reference
number 37 mark on the temperature handle
with the round laser mark on the body.
Tighten the handle with the screw. Put on
the plug.
Very hard water can obstruct the filters
protecting the thermostatic cartridge and
reduce the flow of water. Please clean the
cartridge as follows: Shut off the water
supply of the faucet and open the water
flow handle, then proceed to remove the
cartridge. The cartridge is sensitive,
please be careful.
Make sure the reference mark is aligned
with number 37 before your action.
Remove the handle kit(Fig.1), unscrew the
nut and stopper(Fig.2). Removing the
cartridge cautiously(Fig.3). Clean the
thermostatic cartridge by soaking it in
warm vinegar.
The filters(31) protecting the
faucet device may get obstructed
and reduce water flow. When this
happens, unscrew the bushes
(33, left thread) by a wrench(32,
12mm) and take out the nuts(34),
filters(31) and the check valves
(35) after removing the faucet.
Clean the filters by soaking them
in warm vinegar. Reinstall them
as the figure.(
Note:
Check valves
should reinstall as original
orientation).
21
21-2
21-1
18
17
23
24
25
19
20
22
28
27
26