KohlerPower.com
33 590 04
16
TIP
9
“–” means below.
9
Application wattage indicates when each device is
used by itself.
9
The simultaneous usage of AC and DC power is
possible but total wattage should not exceed the
rated output.
EX:
Generator rated output
2,500 VA
Frequency
Power factor
AC
1.0
–2,380 W
0.8
–1,880 W
DC
—
120 W
(12 V/10 A)
9
The overload indicator light comes on when total
wattage exceeds the application range. (See page
19 for more details.)
1
Overload indicator light
760-021a
1
AE00812
Application range
When using the generator, make sure the total load is within rated output of a genera-
tor. Otherwise, generator damage may occur.
AC
DC
Power factor
1
0.8–0.95
0.4–0.75
(Efficiency 0.85)
PRO 2.8 i
–2,500 W
–2,000 W
–850 W
Rated voltage
12 V
Rated current
10 A