KohlerPower.com
25
33 590 03
AE00812
Application range
When using the generator, make sure the total load is within rated output of a genera-
tor. Otherwise, generator damage may occur.
AC
DC
Power factor
1
0.8–0.95
0.4–0.75
(Efficiency 0.85)
PRO 2.0 iS
–1,600 W
–1,280 W
–544 W
Rated voltage
12 V
Rated current
8 A
NOTICE
9
Do not overload. The total load of all electrical appliances must not exceed
the supply range of the generator. Overloading will damage the generator.
9
When supplying precision equipment, electronic controllers, PCs, electronic
computers, microcomputer-based equipment or battery chargers, keep the
generator a sufficient distance away to prevent electrical interference from
the engine. Also ensure that electrical noise from the engine does not inter-
fere with any other electrical devices located near the generator.
9
If the generator is to supply medical equipment, advice should first be
obtained from the manufacturer, a medical professional or hospital.
9
Some electrical appliances or general-purpose electric motors have high starting
currents, and cannot therefore be used, even if they lie within the supply ranges
given in the above table. Consult the equipment manufacturer for further advice.
TIP
9
“–” means below.
9
Application wattage indicates when each device is
used by itself.
9
The simultaneous usage of AC and DC power is
possible but total wattage should not exceed the
rated output.
EX:
Generator rated output
1,600 VA
Frequency
Power factor
AC
1.0
–1,500 W
0.8
–1,180 W
DC
—
96 W
(12 V/8 A)
9
The overload indicator light comes on when total
wattage exceeds the application range. (See page
10 for more details.)
1
Overload indicator light
1
7DK-021
7PB-F8199-L2.indd 25
2014/01/08 17:07:36
Содержание PRO 2.0 iS
Страница 51: ......
Страница 52: ...PRINTED IN CHINA 2014 01 E O...