Replacing Protective Fuses
NOTE: Comply with technical specifications for
fuses. Using wrong fuse may cause
damage to generator.
Replace fuses (J) in event of failures due to
overcurrents. Before replacing worn fuses
(J) with new ones, always contact a Kohler
portable dealer to determine cause of failure
and overcurrent.
1. Turn MODYS (B) key to OFF position.
Generator stops.
2. Unscrew 12V fuse holder for MODYS (B)
and lighting and 240V fuse holder for
MODYS (B) and working hours counter.
3. Visually check condition of both fuses (J).
4. Replace worn fuse(s) (J) with a new one of
5x20 type, rating 2A.
5. Screw two fuse holders back in.
Transporting Generator
Before transporting generator, check that bolts
are correctly tightened, close fuel valve (P)
and disconnect battery. Generator should be
transported in its normal operating position;
never lay it on its side. Ensure where generator
is to be stored or used is carefully prepared
beforehand.
Repairs/Service Parts
We recommend that you use a Kohler portable
dealer for all maintenance, service, and
replacement parts for engine. To find a Kohler
portable dealer visit KohlerPower.com or call
1-800-544-2444 (U.S. and Canada).
Storage
Long-term storage of your generator will require
some preventative procedures to guard against
deterioration.
NOTE: Do not connect with any electrical
devices (unloaded operation).
If engine will be out of service for 2 months or
more follow procedure below.
1. Add Kohler PRO Series fuel treatment or
equivalent to fuel tank. Run engine 2-3
minutes to get stabilized fuel into fuel system
(failures due to untreated fuel are not
warrantable).
2. Change oil while engine is still warm from
operation. Remove spark plug(s) (X) and
pour about 1 oz. of engine oil into cylinder(s).
Replace spark plug(s) (X) and crank engine
slowly to distribute oil.
3. Clean generator.
4. Store generator in a dry, well-ventilated
place, with cover placed over it. When
covering generator, be sure to do so only
after engine and muffler/shield have
completely cooled down. Generator must
remain in same position as normal operation.
Repairing Minor Faults - MODYS Alarms and Faults
Pictograms Color of
LED
Type of Fault
Issue
Possible Solution
Red
Engine
temperature
Shutdown: abnormal
engine temperature
Allow generator to cool
down and check air
cleaner and vents on
enclosure.
Red
Battery or
charging
alternator
Problem with alternator
charge output or weak
battery
Contact a Kohler
portable dealer.
Red
Oil pressure or
low oil level
Shutdown: incorrect oil
pressure or low oil level
Allow generator to cool
down, top up and check
oil level.
Red
Non-starting fault
3 consecutive
unsuccessful starting
attempts
Check that generator has
been started according to
recommendations in this
manual.
Red
Overspeed
Shutdown: generator
rotation speed
excessive
Contact a Kohler
portable dealer.
Flashing
Red
Speed too low
Shutdown: insufficient
generator rotation
speed
Contact a Kohler
portable dealer.