13
1493623-W2-A
Warning! Turn off the electrical and water supplies before proceeding with
the installation of the shower.
Cover
Screw
Screws
Service
Tunnel
Remove the three screws that hold the cover on and remove the
cover.
Remove the service tunnel.
Caution!
Do not drill into cables or pipes in the wall.
Thoroughly flush the supply pipe.
Determine the direction and route of the incoming water supply:
falling (entering the shower from the top), or rising (entering the
shower from the bottom).
Note: - DO NOT
use an incoming supply entering the shower
directly from the back. Add an elbow to the supply pipe and connect
it as a rising or falling supply.
1
2
Using the installation template supplied, mark the positions of the
three
fixing holes.
Note:
Ensure that there are sufficient lengths of supply pipe and
electrical cable to reach the connection points.
Remove the installation template and drill three holes to suit the
fixing screws and wall plugs.
Rotate the inlet connector to suit the direction of the incoming
water supply.
Secure the shower to the wall with appropriate wall fixings.
3
4
Inlet
Connector
Upper and lower case inserts are supplied and should be fitted.
Note: -
Trim the inserts if necessary to fit incoming electrical or
water supplies before fitting.
Case
Insert
Installation