These instructions must be left with the user

Mira Sport
7.5, 9.0, 9.8 and 10.8 kW

Installation and User Guide

For SPARES, 

ADVICE or REPAIRS 

please call us free 

on 0800 001 4040 

(UK only)

Содержание Mira Sport J03A

Страница 1: ...1 1493623 W2 A These instructions must be left with the user Mira Sport 7 5 9 0 9 8 and 10 8 kW Installation and User Guide For SPARES ADVICE or REPAIRS please call us free on 0800 001 4040 UK only...

Страница 2: ...ction concerning use of the appliance in a safe way and understand the hazards involved 2 Children shall not be allowed to play with the shower 3 DO NOT restrict the water flow from the shower outlet...

Страница 3: ...t mode point handset away from body and make sure that the water temperature has stabilised before continuing to shower 16 Use caution when altering the water temperature always check the temperature...

Страница 4: ...ering the shower 26 The water supplies to this product must be isolated if the product is not to be used for a long period of time If the product or pipework is at risk of freezing during this period...

Страница 5: ...to familiarize yourself with the part names and to confirm that the parts are included Documentation 1 x Electric Shower 2 x Case Inserts 1 x Installation Guide and User Guide 1 x Installation Templa...

Страница 6: ...iagram Inlet Connector Terminal Block Heater Tank Micro Switch L Micro Switch R Solenoid LED LED Housing Push Button Switch BROWN B GREEN D BLUE C RED K BROWN J BROWN G BLACK M BLACK L RED H BLUE E BR...

Страница 7: ...tions and recommendations Follow all warnings cautions and instructions contained in this guide and on or inside the shower Mira Sport electric showers have separate controls for power selection and f...

Страница 8: ...rical Variant 7 5 9 0 9 8 10 8 Nominal Power at 240 V ac 7 5 kW 9 0 kW 9 8 kW 10 8 kW Nominal Power at 230 V ac 6 9 kW 8 3 kW 9 0 kW 9 9 kW Recommended MCB Rating 32 A 40A 45A 45A Maximum Supply Cable...

Страница 9: ...o conditional connection If the main electrical supply fuse is rated less than 80 Amps the local electricity supply company must be contacted to confirm if the electrical supply is adequate This range...

Страница 10: ...rproof flat and even wall surface 8 DO NOT fit the shower to the wall and tile up to the case 9 DO NOT seal the gap between the shower and the wall surface 10 The showerhead should be positioned so th...

Страница 11: ...red rawl plug and a no 8 x 1 countersunk brass or stainless steel screw should be used For other wall structures such as panels alternative fixings may be required A minimum of 3 fixing screws should...

Страница 12: ...t be provided from the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must be provided with means for local...

Страница 13: ...directly from the back Add an elbow to the supply pipe and connect it as a rising or falling supply 1 2 Using the installation template supplied mark the positions of the three fixing holes Note Ensu...

Страница 14: ...to misaligned pipework or electrical cables Strip back sufficient outer cable insulation to enable routing to terminal block Fit an earth sleeve to the earth wire Tighten the screws in the terminal b...

Страница 15: ...cked with the product LOW HIGH ECO POWER TEMPERATURE Do not use alternative screws to secure the cover This can cause internal damage to the appliance Do not seal around the back of appliance This com...

Страница 16: ...Turn temperature control to the cold position Turn power control to low TEMPERATURE LOW HIGH ECO POWER 1 2 Switch on the electrical supply 3 Push START STOP button Light in the button illuminates 4 W...

Страница 17: ...Temperature will rise slightly 10 5 10 secs COLD HOT 5 10 secs COLD HOT Turn power control to High LOW HIGH ECO POWER 11 Temperature will rise further 12 10 secs COLD HOT 5 10 secs COLD HOT 13 Adjust...

Страница 18: ...temperature adjustments to stabilise and reach the showerhead Check the water temperature before entering shower Switch off the electrical supply Push the START STOP button to turn ON the appliance L...

Страница 19: ...tone This is quite normal in use The Effect of Seasonal Changes Incoming mains water temperature is not constant throughout the seasons of the year i e cooler during the winter warmer during the summe...

Страница 20: ...the showering temperature to increase Showering temperature will stabilise to within 6 C band if other outlets are opened whilst showering providing the minimum pressure does not fall below 70 kPa 0...

Страница 21: ...ce if necessary ON ECO HIGH Water pressure below minimum required for shower operation Make sure incoming mains water stopcock and or shower isolating valve is fully turned on ON ECO HIGH Temperature...

Страница 22: ...y ON ANY Possible failure of flow valve microswitch or heater tank Use a suitable device to check the continuity of the microswitch or heater tank and replace parts as necessary Water will not turn of...

Страница 23: ...eep the showerhead nozzles clear or inspect the hose for blockage or internal external collapse can restrict the flow rate from the shower This may cause damage to the shower or result in the temperat...

Страница 24: ...re removing the cover 2 4 5 3 6 1 Inlet Connector Assembly Inlet Filter Screws Service Tunnel Screw Cover Hose Washer Remove the shower hose Note Retain the hose washer for further use Remove the thre...

Страница 25: ...438 7 5kW 1746 439 9 0kW 1746 440 9 8kW 1746 441 10 8kW Heater Tank includes microswitches 1746 449 Terminal Block 1746 436 Thermal Switch 1746 447 Outlet Connector A B B A A A 1746 442 1746 443 Flow...

Страница 26: ...26 1493623 W2 A Notes...

Страница 27: ...27 1493623 W2 A Notes...

Страница 28: ...tenham Gloucestershire GL52 5EP 14648 Guarantee Your product has the benefit of our manufacturer s guarantee which starts from the date of purchase This guarantee only applies in the United Kingdom an...