These instructions must be left with the user

Mira Galena
9.8 kW

Installation and User Guide

For SPARES, 

ADVICE or REPAIRS 

please call us free 

on 0800 001 4040 

(UK only)

Содержание MIra 1.1634.117

Страница 1: ...1 1062246 W2 N These instructions must be left with the user Mira Galena 9 8 kW Installation and User Guide For SPARES ADVICE or REPAIRS please call us free on 0800 001 4040 UK only ...

Страница 2: ...uction concerning use of the appliance in a safe way and understand the hazards involved 2 Children shall not be allowed to play with the shower 3 DO NOT restrict the water flow from the shower outlet temporarily bending the shower hose or blocking the shower head while in use can cause a hot shot of water to be discharged 4 Cleaning and user maintenance shall not be made by children without super...

Страница 3: ...et mode point handset away from body and make sure that the water temperature has stabilised before continuing to shower 16 Use caution when altering the water temperature always check the temperature before continuing to shower 17 Switch the shower off at the electrical isolating switch when not in use This is recommended with all electrical appliances 18 Installation of the shower must be carrie...

Страница 4: ... they should also be drained of water 26 If the shower is dismantled during installation or servicing then upon completion an inspection must be made to ensure all electrical connections are tight and that there are no leaks 27 This appliance is intended to be permanently connected to the water mains and not connected by a hose set 28 The water inlet of this appliance shall not be connected to a w...

Страница 5: ... 1 x Olive 1 x Compression Nut 1 x Mira Galena Documentation 1 x Installation and User Guide 1 x Installation Template 1 x Guarantee and Registration Document BROWN BROWN BROWN BROWN RED RED RED BROWN BROWN GREEN BLUE BLUE BLACK BLACK BLACK GREEN Thermal Cutout Disc Tank Connection Load Inlet Connector Pressure Power Selector Switch Solenoid Valve Start Stop L E D START STOP L E N ...

Страница 6: ...ese can result from taps being turned on or off or a toilet being flushed An individual light indicates START STOP The Mira Galena comes complete with a set of Mira Energise Shower Fittings A 9 8 kW 240 V AC 9 0 kW 230 V AC heater with Mira Energise adjustable spray handset with four different spray actions start soothe force and eco Supplied complete with flexible hose clamp bracket assembly slid...

Страница 7: ...with 3 mm contact separation Appliance Sealing Rating IP X4 Suitable for installation in Zone 1 MaximumAmbient Temperature 30 C Minimum Ambient Temperature 2 C Plumbing Variant Galena 9 8 Minimum Dynamic Pressure 70 kPa 0 7 bar Maximum Dynamic Pressure 500 kPa 5 bar Maximum Static Pressure 1000 kPa 10 bar Minimum Static Pressure 20 kPa 0 2 bar Maximum Inlet Temperature 30 C Minimum Inlet Temperatu...

Страница 8: ...riod of one year from the date of purchase For terms and conditions refer to section Customer Services Guarantee The Mira Galena shower complies with the following European directives 2006 95 EC Low Voltage Directive 2004 108 EC EMC Directive The Mira Galena shower is a high power appliance and is subject to conditional connection If the main electrical supply fuse is rated less than 80 Amps the l...

Страница 9: ...erproof flat and even wall surface 8 DO NOT fit the shower to the wall and tile up to the case 9 DO NOT seal the gap between the shower and the wall surface 10 The showerhead should be positioned so that it discharges down the centre line of the bath or across the opening of a shower cubicle 11 The showerhead must be directed away from the shower unit during normal use the showerhead must not spra...

Страница 10: ...l installation until the plumbing has been completed and checked for leaks Hose retaining ring fitted and shower fittings fixed at a suitable height preventing dirty water backflow Note There will be occasions when the hose retaining ring will not provide a suitable solution for Fluid Category 3 installations in these instances an outlet double check valve must be fitted this will increase the req...

Страница 11: ...e consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must be provided with means for local disconnection that is incorporated into the fixed wiring in accordance with the relevant local wiring regulations This must be a double pole switch which has at least 3 mm contact separation in each pole The switch can b...

Страница 12: ...ed off at the mains and the appropriate circuit fuse removed if applicable Note An installation template is supplied to help you install the shower Remove the three cover retaining screws the cover and the service tunnel Installation of Mira Galena Wall fixings are not supplied For solid wall structures a red rawl plug and a no 8 x 1 countersunk brass or stainless steel screw should be used For ot...

Страница 13: ...ixing holes Ensure the position of these holes do not come in line with any buried cables or pipework Make sure that sufficient electrical supply cable is available for connection to the terminal block Drill and plug the top two fixing holes Secure the appliance to the wall with appropriate screws Drill the bottom fixing hole with the product in place Alternative fixings not supplied may be necess...

Страница 14: ...ure they fit correctly Do not overtighten screws Do not use alternative screws to secure the Cover This can cause internal damage to the appliance Do not seal around the back of appliance When fitting the cover position the controls to correspond with the internal drive features as shown Caution Handle the cover assembly with care Cover Cover Retaining Screw ...

Страница 15: ...15 1062246 W2 N Cold Water Supply Pipe Bottom Entry Service Tunnel Fixing Screw Holes For Cover Retaining Screws Case Insert Electrical Supply Cable Terminal Block Inlet Connector Assembly Heater Tank ...

Страница 16: ...lease read through the section User Instructions before continuing Turn control to full cold Turn the water supply fully on Check for water leaks Set control to I Switch on electrical supply Press the Start Stop button Water will be at full force and at a cool temperature Turn the control slowly Temperature remains cool and flow is reduced Electrical supply is turned off at the mains 0 5 Secs 1 4 ...

Страница 17: ... in use Turn control to full cold The temperature will rise slightly Set control to II 0 10 Secs 12 11 10 The temperature will rise further Adjust temperature as required Flow rate will adjust automatically The shower will purge from its tank for a few seconds Residual water may drain over a few minutes Set control to III 5 10 Secs 0 5 Secs 13 15 14 16 Press STOP 18 19 17 Isolate power _ _ ...

Страница 18: ...ns How Your Electric Shower Works The warmer the shower the lower the flow rate and vice versa Heated water is produced by adjusting the flow of cold water passed through a heater tank The shower has three heater settings _ COLD _ _ ...

Страница 19: ...rature across the range from hot to cold whilst also dealing with fluctuations in electrical and water supplies As a result there is a temperature limit the shower cannot go beyond For safety this temperature is factory set and cannot be adjusted to make the shower hotter or colder Thermostatic Temperature Stable THERMOSTATIC ELECTRIC SHOWER ORDINARY ELECTRIC SHOWER ...

Страница 20: ...dset after the shower has been turned off This may drain over a few minutes Press the Start Stop button 2 Switch on electrical supply 1 Set to desired position 3 Residual water may drain over a few minutes 8 4 Check water temperature before entering shower 5 Allow 10 15 seconds for any temperature adjustments to reach the handset 6 Press STOP button Shower will continue to run for a few seconds be...

Страница 21: ... the required operating parameters refer to section Specifications For a cold shower select I For a summer warm shower select II For a winter warm shower select III During extremes of mains water supply temperature adjust heater setting to obtain a better showering temperature The Effect of Seasonal Changes The Effect of Other Water Devices Example of how shower temperature stabilises due to press...

Страница 22: ...c k a n d o r appliance isolating valve is fully turned on Temperature dial or Heater setting too high Turn the heater selector knob to setting II or turn the temperature control until a cooler temperature is achieved Thermostatic mechanism is faulty or damaged Replace U n a b l e t o s e l e c t a cool enough shower ON III Due to the rise in mains water supply temperature the Heater setting may b...

Страница 23: ...m of 0 7 bar Note If other appliances are operating pressure may drop below 0 7 bar Other outlets e g toilet garden hose washing machine etc drawing water while the shower is being used Turn off other appliances whilst shower is in use Showerhead blocked Remove and clean OFF ANY Service tunnel or cover not fitted correctly causing Start Stop button not to operate Check case inserts are cut and fit...

Страница 24: ...rson should drain them of water Symptom Start Stop Light Heater Setting I II III Probable Cause Possible Remedy No change in temperature between I II III settings ON ANY Insufficient mains water pressure Contact local water company Possible failure of flow valve microswitch or heater tank Check the continuity of the microswitch or heater tank and replace parts as necessary Water will not turn off ...

Страница 25: ...showerhead nozzles clear or inspect the hose for blockage or internal external collapse can restrict the flow rate from the shower This may cause damage to the shower or result in the temperature delivered to the user rising to unsafe levels with a risk of scalding You MUST ALWAYS check the temperature before using the shower Many household and commercial cleaners including hand and surface cleani...

Страница 26: ...he electrical supply is turned off at the mains and that the water supply is fully turned off Remove the three screws and the cover Inlet Filter Cleaning Renewing Read the section Important Safety Information first Warning There are no user serviceable parts inside the shower Servicing of the shower must only be carried out by qualified competent personnel following the instructions provided in th...

Страница 27: ...sembly 416 38 Clamp Bracket Inlet 416 41 Thermal Switch 416 48 Latching Switch 416 51 Solenoid Coil 1563 519 Terminal Block Assembly 1563 845 Thermostatic Valve Heater Tank 9 8 kW 240 V AC includes microswitches 1563 534 Outlet Connector Assembly 1563 537 Temperature Control Belt Thermostatic 1563 538 Temperature Cam Pulley 1563 539 Switching Assembly 1563 540 Inlet Valve Assembly 1829 063 1829 06...

Страница 28: ... Gloucestershire GL52 5EP 14648 Guarantee Your product has the benefit of our manufacturer s guarantee which starts from the date of purchase This guarantee only applies in the United Kingdom and Republic of Ireland Activating Your Guarantee Registering your guarantee is quick and simple To ensure your product is covered please register online Scan the QR code to activate your guarantee now or cal...