Kohler Memoirs K-724-G96 Скачать руководство пользователя страница 2

Memoirs

®

60" x 33-3/4" alcove BubbleMassage

 air bath

K-724-G96

1-1/2"
Bath Drain

No change in measurements if connected
with drain illustrated. (K-7161-AF)

Blower Motor/Control Access
34" (864 mm) W x
15" (381 mm) H

60" (1524 mm)

32"
(813 mm)

16"
(406 mm)

1-13/16" (46 mm)

8-1/2" (216 mm)

2-7/8"
(73 mm)

3"
(76 mm)

NOTE:  Blower protrusion
beyond the rim.

1-1/2"
(38 mm)

17-7/16"
(443 mm)

1/8" (3 mm)

33-3/4" (857 mm)

1" (25 mm)

3-1/4"
(83 mm)

Lumbar
Angle 31°

Required Electrical Service

One dedicated circuit required, protected with Class A Ground-
Fault Circuit-Interrupter (GFCI). Outside North America, this
device may be known as a Residual Current Device (RCD).

Blower:

240 V, 15 A, 50/60 Hz

Technical Information

All product dimensions are nominal.

Installation:

Three-wall alcove

Drain location:

Right

Basin area, bottom:

45" x 23" (1143 mm x 584 mm)

Basin area, top:

54" x 25" (1372 mm x 635 mm)

Weight:

390 lbs (176.9 kg)

Minimum floor load:

61 lbs/ft² (297.8 kg/m²)

Water depth:

11-5/8" (295 mm)

Water capacity:

52 gal (196.8 L)

Electrical component

rating:

Blower: 240 V, 5 A, 50/60 Hz

Blower speed:

Variable

Notes

Measure your actual product for rough-in
details.

Install this product according to the installation
instructions.

The hot water supply should be 70% of the
capacity of the bath or greater. Installations will
vary.

If relocating the blower motor, do not relocate
or alter the PVC tee or coiled flexible tubing
connected to the blower. Follow the blower
relocation instructions exactly. Provide access
for servicing the blower.

ADA compliant when installed to the specific
requirements of these regulations.

1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to 

www.kohler.com

.

7-30-2022 00:37 - US/CA
 