background image

Product Information

Left drain

K-723-H2

shown

Right drain

K-724-H2

not shown

Required accessories:
Jet trim kit

K-9696

Fixture*:

basin area

top area

weight

Bathing

well

45

(114.3 cm)

x 23

(58.4 cm)

54

(137.2 cm)

x 25

(63.5 cm)

390 lbs

(176.9 kg)

water depth

capacity

To

overflow

11-5/8

(29.5 cm)

52 gal

(196.8 L)

* Approximate measurements for comparison only.

Pump

Heater

V

A*

1.5 hp

1.5 kW

240

11

* Approximate measurements for comparison only.

Required Electrical Service

Dedicated circuit required, protected with a Class A

Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage

Circuit-Breaker (ELCB):
Pump/control

208-240 V, 20 A, 50/60 Hz

Locate the outlet behind the whirlpool and within 24

(61 cm) of the pump.

Installation Notes

NOTE:

Pump protrusion beyond rim.

Install this product according to the installation guide.
Floor support under whirlpool must provide for a minimum of

1500 lbs (680.4 kg).
Fixture conforms to ASME Standard A112.19.1M. All dimensions

are nominal.

Pump/Control Access

33-3/4" (85.7 cm)

1-1/2" OD

1-13/16" (4.6 cm)

1/8" (3 mm)

8-1/2" (21.6 cm)

60" (152.4 cm)

2-7/8" (7.3 cm)

3" (7.6 cm)

1" (2.5 cm)

Note: Pump protrusion beyond rim

16"
(40.6 cm)

32"
(81.3 cm)

1-1/2"
(3.8 cm)

3-1/4"
(8.3 cm)

17-7/16"
(44.3 cm)

30" (76.2 cm) W x
15" (38.1 cm) H Min

No change in measurements with drain 
shown. (K-7161-AF or K-7161M-AF)

Recommended faucet area.

1019706-1-C

2

Kohler Co.

Содержание Memoirs K-723

Страница 1: ...bers are for Mexico i e K 12345M Los números de productos seguidos de M corresponden a México Ej K 12345M Français page 3 Español página 4 USA 1 800 4 KOHLER Canada 1 800 964 5590 México 001 877 680 1310 kohler com K 723 1019706 1 C 2006 Kohler Co ...

Страница 2: ...ge Circuit Breaker ELCB Pump control 208 240 V 20 A 50 60 Hz Locate the outlet behind the whirlpool and within 24 61 cm of the pump Installation Notes NOTE Pump protrusion beyond rim Install this product according to the installation guide Floor support under whirlpool must provide for a minimum of 1500 lbs 680 4 kg Fixture conforms to ASME Standard A112 19 1M All dimensions are nominal Pump Contr...

Страница 3: ... ELCB Pompe contrôle 208 240 V 20 A 50 60 Hz Localiser la prise derrière la baignoire à hydromassage et dans les 24 61 cm de la pompe Notes pour l installation REMARQUE Pompe dépassant au delà du rebord Installer ce produit selon le guide d installation Le sol sous la baignoire à hydromassage doit pouvoir soutenir une charge minimale de 1500 lbs 680 4 kg L appareil sanitaire est conforme à la norm...

Страница 4: ...un disyuntor de fuga a tierra ELCB Bomba control 208 240 V 20 A 50 60 Hz Coloque el tomacorriente detrás de la bañera de hidromasaje y a menos de 24 61 cm de la bomba Notas para la instalación NOTA La bomba sobresale del borde Instale este producto conforme a la guía de instalación El soporte del piso debajo de la bañera de hidromasaje debe poder soportar como mínimo 1500 lbs 680 4 kg El producto ...

Отзывы: