-6-
7. Toilet does not activate.
A. Chain is not connected to lift rod or
flush valve.
A. Reconnect the chain.
1. Fill valve turns on/off by itself without
toilet being flushed.
A. No slack in flapper chain assembly,
holding flapper off seat.
B. Flush valve flapper ball worn, dirty
or misaligned with flush valve seat;
or seat corroded so flapper will not
seal.
C. Refill tube pushed too far down in
overflow pipe.
A. Adjust flapper chain assembly for
proper slack.
B. Inspect, clean and, if necessary,
replace flapper ball and/or seat.
C. Attach refill
to overflow pipe
above the water line.
tube
2.
valve continues to run, allowing
water to enter tank.
A.
valve seal (located under fill valve
cap) may be cracked or split.
B. Tank water level set above overflow
level.
C. Water leaking past flush ball.
A. Replace seal.
B.
C. Replace flush ball.
D. Turn trip lever nut clockwise to loosen
until trip lever no longer binds.
Fill
Fill
D. Trip lever binding, holding flush ball
open.
During fill cycle, hold float under water
a few seconds to allow it to fill with
water ballast. Refer to "Minor
Adjustment of Water Level" for
waterline adjustment.
3. Incorrect water level height.
A. Valve float cup does not contain
enough water to provide required
ballast.
B. Float height incorrect.
A. During fill cycle, hold float under water
a few seconds to allow it to fill with
water ballast.
B. Refer to "Minor Adjustment of Water
Level" for waterline adjustment.
4. Long or noisy tank fill cycle.
A. Plugged valve inlet or supply line.
A. Perform Corrective Action 2.A.
5. Poor flush.
A. Water level is too low.
B. Trapway or rim holes are obstructed.
C. Soil pipe or vent is obstructed.
D. Supply shut-off valve not fully open.
E. Low water level in bowl due to refill
tube being plugged or out of overflow
tube.
A. Adjust
water level.
B. Unclog trapway; clean rim holes.
C. Clear obstruction from soil pipe or
vent.
D. Open supply shut-off valve.
E. Clean or straighten refill tube; attach
refill tube to overflow tube.
tank
6. Toilet overflows.
A. Toilet trapway is obstructed.
B. Soil pipe or vent is obstructed.
A. Use plunger to unclog.
B. Clear obstruction from soil pipe or
vent pipe.
CLOSE
E
G
2mm
Fasten the snap along "CLOSE"
direction.
Float adjustment instructions:
Make
sure the height of surface E is 2-4mm
lower than surface G.
Fig.#11d
11d
Fig.#11e
11e
Screw
E
Float
Water Cup
G
SCALE
5:1
OPEN
CLOSE
1033003-T01-N