7. Toilet does not activate.

A. Chain is not connected to lift rod or

flush valve.

A. Reconnect the chain.

1. Fill valve turns on/off by itself without

toilet being flushed.

A. No slack in flapper chain assembly,

holding flapper off seat.

B. Flush valve flapper ball worn, dirty

or misaligned with flush valve seat;
or seat corroded so flapper will not
seal.

C. Refill tube pushed too far down in

overflow pipe.

A. Adjust flapper chain assembly for

proper slack.

B. Inspect, clean and, if necessary,

replace flapper ball and/or seat.

C. Attach refill

to overflow pipe

above the water line.

tube

2.

valve continues to run, allowing

water to enter tank.

A.

valve seal (located under fill valve

cap) may be cracked or split.

B. Tank water level set above overflow

level.

C. Water leaking past flush ball.

A. Replace seal.

B.

C. Replace flush ball.
D. Turn trip lever nut clockwise to loosen

until trip lever no longer binds.

Fill

Fill

D. Trip lever binding, holding flush ball

open.

During fill cycle, hold float under water

a few seconds to allow it to fill with
water ballast. Refer to "Minor
Adjustment of Water Level" for
waterline adjustment.

3. Incorrect water level height.

A. Valve float cup does not contain

enough water to provide required
ballast.

B. Float height incorrect.

A. During fill cycle, hold float under water

a few seconds to allow it to fill with
water ballast.

B. Refer to "Minor Adjustment of Water

Level" for waterline adjustment.

4. Long or noisy tank fill cycle.

A. Plugged valve inlet or supply line.

A. Perform Corrective Action 2.A.

5. Poor flush.

A. Water level is too low.
B. Trapway or rim holes are obstructed.
C. Soil pipe or vent is obstructed.

D. Supply shut-off valve not fully open.
E. Low water level in bowl due to refill

tube being plugged or out of overflow
tube.

A. Adjust

water level.

B. Unclog trapway; clean rim holes.
C. Clear obstruction from soil pipe or

vent.

D. Open supply shut-off valve.
E. Clean or straighten refill tube; attach

refill tube to overflow tube.

tank

6. Toilet overflows.

A. Toilet trapway is obstructed.
B. Soil pipe or vent is obstructed.

A. Use plunger to unclog.
B. Clear obstruction from soil pipe or

vent pipe.

CLOSE

E

G

2mm

Fasten the snap along "CLOSE"
direction.

Float adjustment instructions:

Make

sure the height of surface E is 2-4mm
lower than surface G.

Fig.#11d

11d

Fig.#11e

11e

Screw

E

Float

Water Cup

G

SCALE

5:1

OPEN

CLOSE

1033003-T01-N

Содержание MEMOIRS K-3429T

Страница 1: ...454T MEMOIRS Classic Toilet K 3429T C Includes Elongated Bowl K 4254T Tank K 4454T French Curve Quite close Seat K 4713T MEMOIRS Stately Toilet K 3439T Includes Elongated Bowl K 4254T Tank K 4464T MEMOIRS Stately Toilet K 3439T C Includes Elongated Bowl K 4254T Tank K 4464T French Curve Quite close Seat K 4713T MEMOIRS Stately Toilet K 3439T S Includes Elongated Bowl K 4254T Tank K 4464T French Cu...

Страница 2: ...serve all local plumbing and building codes Shut off the water supply Seat post holes are on 140mm 5 1 2 centers 51mm 2 passageway Water depth from the rim Ensure that the new drain has the correct roughing in dimension Carefully inspect the new fixture for any sign of damage For new construction refer to the dimensions in for locating the shut off valve Fixture dimensions are nominal and conform ...

Страница 3: ...use of cement NOTICE 8mm T Fig 3 3 Closet Flange T bolts T Fig 4 4 Supply Shut Off Valve Closet Flange Centerline 127mm 305mm 127mm Remove the old gasket from the floor and the closet flange with a putty knife Remove the old T bolts and discard them If the new toilet is not installed immediately temporarily stuff a rag into the closet flange NOTICE TO INSTALL SUPPLY SHUT OFF VALVE Install the supp...

Страница 4: ... seal Over tightening may cause breakage or chipping of the vitreous china CAUTION Risk of personal injury or product damage Fig 7 7 Brass Nut Washer Gasket Tank Bolt Shape of the actual gasket may not be the same as shown but installation method remains the same Supply Shank Supply Shut Off Valve Fig 8 8 TO CONNECT WATER SUPPLY Flexible hose not provided are recommended to connect the supply line...

Страница 5: ...T WITH BALLAST Test flush the toilet Periodically check all connections for leaks for several days following installation Set the tank cover in place on the tank Fig 10 10 Float Fill Valve Cap OPEN MINOR ADJUSTMENT OF WATER LEVEL Move the snap along OPEN direction To lower water level Move water cup down to a proper height and rotate screw anticlockwise to achieve the desired water level Refer to ...

Страница 6: ... of Water Level for waterline adjustment 3 Incorrect water level height A Valve float cup does not contain enough water to provide required ballast B Float height incorrect A During fill cycle hold float under water a few seconds to allow it to fill with water ballast B Refer to Minor Adjustment of Water Level for waterline adjustment 4 Long or noisy tank fill cycle A Plugged valve inlet or supply...

Страница 7: ... 7 3 A B A B 6 A B A B 7 A A 5 A B C D E A B C D E 1 A B C A B C 2 A B C D A C D B 4 A A 2A 1033003 T01 N ...

Страница 8: ... in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage 8 CAUTION Don t use any cement while installing the toilet WARNING Risk of product damage Heat expansion of the toilet may damage the f...

Отзывы: