Kohler MEMOIRS 22559T-4V Скачать руководство пользователя страница 2

   

                                                                               

1372307-2A-A                                 

                                                                                                                   2   

  

   

                                                                               

1372307-2A-A                         

                                                                                                                           3  

  

9

10

10

14

11

12

13
11

How to Maintain the Handshower

Any debris or mineral build-up may cause the flow stream distorted or 

reduce the flow rate. To remove the debris or mineral build-up, run 

water through the handshower, firmly press or rub your finger back and 

forth across the rubber nozzles.

INSTALLATION CHECKOUT

Ensure that all coupling nuts are tight. Ensure that the handles are in 

the off position. 

Turn on main water supply, and check for leaks. Repair as needed.

Remove the aerator(14) and handshower(10). Turn on faucet handle. 

Run hot and cold water through spout for about one minute to remove 

any debris. Remove and clean the screen washer. Check for leaks. 

Remove any debris. Shut off the faucet. Reinstall the aerator and 

handshower.

All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft 

cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc, which could adversely 

affect the finish and are not recommended for cleaning.

Do not use abrasive cleaners or solvents on Kohler faucets and fittings. 

CLEANING INSTRUCTIONS

HANDLE OPERATION

Turn the left handle clockwise for hot water. Turn the right handle counter-clockwise for cold water. 

Lift the diverter knob gently for handshower. Press the diverter knob back in the normal position for bath spout.

Press the buttons of the handshower to change the water flow. 

INSTALLATION

How to Install the Faucet

Shut off water supply. Cut away the extending part of the base 

protector(1) in accordance with the tile surface. Remove the plug(2) 

from the base. Remove the protector(3) from the faucet. 

Slide up the escutcheon kit(4). Install the faucet. 

NOTE: 

Keep the 

faucet vertical to base, to avoid damaging the O-rings on the bottom. 

Keep the spout pointing to tub. Fix the faucet to the base with the 

screws(5) and washers(6) through the flange(7). Tighten the screws 

with hex wrench(8).

Slide down the escutcheon kit, make sure it is against the finished floor.

How to Install the Handshower

If needed, install the restrictor(9) into the handshower(10). Put the 

washers(11) into the hose(12). Connect the hose to the connector(13) 

of the diverter kit and handshower. Tighten all the connections. 

Hang the handshower on the bracket. 

5

4

7

8

1

6

2

3

Отзывы: