Mariposa

®

72" x 36" Heated BubbleMassage

 air bath w/ Bask

®

K-1257-GHRAW

1-1/4" 
(32 mm)

3/8"
(10 mm) R

Integral Flange Detail

No change in measurements if connected
with drain illustrated.  (K-7272)

72" (1829 mm)

17-15/16"
(456 mm)

1-13/16"
(46 mm)

10-1/4"
(260 mm)

Lumbar
Angle 42°

5"
(127 mm)

15-1/4"
(387 mm)

1-1/2"
Bath Drain

6-1/8"
(156 mm)

1"
(25 mm)

20"
(508 mm)

36" (914 mm)

21-1/4"
(540 mm)

1-1/4"
(32 mm)

Required Electrical Service

Two dedicated circuits required, protected with Class A Ground-
Fault Circuit-Interrupter (GFCI). Outside North America, this
device may be known as a Residual Current Device (RCD).

Blower, Heated

Surface:

120 V, 15 A, 60 Hz

Air bath:

120 V, 15 A, 60 Hz

Technical Information

All product dimensions are nominal.

Installation:

Three-wall alcove

Drain location:

Right

Basin area, bottom:

47-15/16" x 20-1/16" (1218 mm x
510 mm)

Basin area, top:

65-3/8" x 25" (1660 mm x 636 mm)

Weight:

121 lbs (54.9 kg)

Minimum floor load:

41 lbs/ft² (200.2 kg/m²)

Water depth:

13-3/8" (340 mm)

Water capacity:

72 gal (272.5 L)

Electrical component

rating:

Blower: 120 V, 10 A, 60 Hz
Heated Surface: 120 V, 0.5 A, 60 Hz, 65
W
Air bath: 120 V, 5 A, 60 Hz

Notes

Measure your actual product for rough-in
details.

Install this product according to the installation
instructions.

The hot water supply should be 70% of the
capacity of the bath or greater. Installations will
vary.

Remote blower installation kit K-1446 is
available for relocating the blower. Provide
access for servicing the blower.

Do not relocate or alter the PVC tee or coiled
flexible tubing connected to the blower. Follow
the blower relocation instructions exactly.

1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to 

www.kohler.com

.

10-9-2022 01:11 - US/CA
 