การทําความสะอาดหลังการติดตั้ง

CLEANING INSTRUCTIONS

Clean the Filtration System

The faucet includes connector assembly

with high quality filtration system. If there 

is a lot of debris in the supply pipes or the 

quality of water is bad, it will cause the 

flow in bad condition. Please clean the 

filtration system as following steps: 

1) Turn clockwise the adjustment bolts (30) 

on the connector assemblies with the hex 

wrench (31), in order to close the connector 

assemblies;

2) Screw off the connector caps (33)

counterclockwise with the special key (34);

3) Remove and clean the filters (32), then

reinstall them;

4) Tighten the connector caps (33) 

clockwise with the special key (34). Turn 

counterclockwise the adjustment bolts (30)

on connector assemblies with the hex 

wrench (31).

If necessary,you can screw off and clean

theaerator ofthe faucet,then reinstall it to

improve the flow condition.

NOTE:

 the strainer must be fit back to the 

spout after it is cleaned. 

32

33

34

30

31

28

29

Turn the handle to the middle position of 

the temp adjusting range (For mixed faucet).

Insert the aerator key (29) into the aerator 

slot and take off the aerator (28) by rotating 

it counter-clockwise. Put hands into the 

sensing range under the outlet. Flush water 

through the faucet debris. Remove any 

debris from the aerator assembly (28). Shut 

the main water supply and reinstall the 

aerator assembly (28). Finally, open the

main water supply.            

Clean the Aerator Assembly

ทําความสะอาดปากกอก

หมุนมือบิดปรับอุณหภูมิไปยังตําแหน่งกึ�งกลาง 

(สําหรับก๊อกผสม) ถอดปากก๊อก (28) ออกด้วย 

กุญแจไขปากก๊อก (29) ยื�นมือในระยะตรวจจับ

ของเซ็นเซอร์ เปิดนํ�าทิ�งไว้สักครู่เพื�อชะล้าง

สิ�งสกปรกออกจากปากก๊อก 

ทําความสะอาดปากก๊อก (28) ปิดวาล์วนํ�าแล้ว 

ประกอบปากก๊อก (28) กลับเข้าที� จากนั�นจึง 

เปิดวาล์วนํ�าหลัก

ทําความสะอาดฟลเตอร

ผลิตภัณฑ์นี�ประกอบด้วยชุดข้อต่อพร้อมฟิลเตอร์

คุณภาพสูง หากมีเศษสิ�งสกปรกปะปนมากับ 

นํ�าประปาหรือนํ�าประปามีคุณภาพไม่ดี 

ปัจจัยดังกล่าวอาจส่งผลต่ออัตราการไหลได้ 

ทําความสะอาดฟิลเตอร์โดยปฏิบัติตามขั�นตอน

ดังนี�:

1) หมุนโบลท์ปรับอัตราการไหลของนํ�า (30) 

ตามเข็มนาฬิกาด้วยประแจแอล (31) เพื�อปิด

ชุดข้อต่อ

2) หมุนฝาปิดวาล์ว (33) ทวนเข็มนาฬิกาด้วย

กุญแจพิเศษ (34)

3) ถอดฟิลเตอร์ (32) ออกมาทําความสะอาด 

จากนั�นประกอบฟิลเตอร์กลับเข้าที�

4) หมุนฝาปิดวาล์ว (33) ตามเข็มนาฬิกาด้วย

กุญแจฝาปิดวาล์ว (34) จากนั�นหมุนโบลท์ปรับ

อัตราการไหลของนํ�า (30) ทวนเข็มนาฬิกาด้วย

ประแจแอล (31)

ถอดปากก๊อกออกมาทําความสะอาดหากจําเป็น

ขอสังเกต:

 อย่าลืมประกอบฟิลเตอร์กลับเข้าที�

หลังทําความสะอาด

7

©2014 Kohler Co.

1115767-X2-A

สําหรับทุกพื้นผิว:

  ทําความสะอาดด้วยนํ�าอุ่นและสบู่อ่อนๆเช็ดพื�น

ผิวผลิตภัณฑ์ให้แห้งด้วยผ้านุ่ม  ผลิตภัณฑ์ทําความสะอาดบางประเภท

มีส่วนผสมของสารเคมี  เช่น  แอมโมเนีย,  คลอไรด์,  ผลิตภัณฑ์

ทําความสะอาดห้องนํ�า ฯลฯ ซึ�งอาจทําให้พื�นผิวผลิตภัณฑ์เสียหายได้

จึงไม่แนะนําให้ใช้ในการทําความสะอาด  ห้ามใช้ผลิตภัณฑ์ทําความ

สะอาดที�มีฤทธิ�กัดกร่อน

All Finishes: 

Clean the finish with a mild soap and warm 

water. Wipe entire surface completely dry with a clean soft 

cloth. Many cleaners may contain chemicals, such as 

ammonia, chlorine, toilet cleaner etc. which could adversely 

affect the finish and are not recommended for cleaning. 

Do not use abrasive cleaners or solvents on Kohler 

faucets and fittings.

Содержание MARGAUX

Страница 1: ...window when installing or cleaning the faucet 4 For new installations install the faucet and drain to the lavatory before installing the lavatory 5 As for DC type faucets please pay special attention...

Страница 2: ...19047T Escale Vessel Lavatory K 2200T G Conical Bell Above Counter K 2661X K 4819 Escale K 19047T Conical Bell K 2200T G 174 G 1 2 ROUGH IN DIMENSION 54 72 Output DC 3 V DC3 Input AC 220 V AC220 54 66...

Страница 3: ...ire 9 and supply hose 1 into the hole 5 from under side of the lavatory From underside of the lavatory slide the rubber washer 6 meter washer 7 and xed nut 8 onto the mounting stud 2 Tighten nut 8 to...

Страница 4: ...n power supply and control board If you faucet is AC version please let the black green line in the control board through the U gap and connect with the line of AC power box Connect the red and white...

Страница 5: ...24 Tighten the locknut 25 by hand from the underside of the xture Remove any excess putty NOTE Do not try to change the position of the drain after the locknut 25 is tightened or you may break the pu...

Страница 6: ...Suggested wire AC connection wire should with insulated protecting layer or sleeve and the section should be bigger than 0 5 mm2 The section of DC connection wire should be bigger than 0 3mm2 The conn...

Страница 7: ...l it to improve the flow condition NOTE the strainer must be fit back to the spout after it is cleaned 32 33 34 30 31 28 29 Turn the handle to the middle position of the temp adjusting range For mixed...

Страница 8: ...wire connection occurs to DC terminal of the power box provided AC supply functions normally 3 In normal condition the water will ow and the indicator will ash one time when objects are inducted The i...

Страница 9: ...DC or AC connector may not 3 Reconnect the connector ow out connect well No water ow while 1 Just nishing installation 1 Wait for 10 minutes the indicator ashes 2 The connector assemblies are closed...