Kohler KUMIN 99474T-C4 Скачать руководство пользователя страница 2

   

                                                                          

1265602-2A-E          

                                                                                                                                          2  

  

   

                                                                          

1265602-2A-E           

                                                                                                                                         3

  

INSTALLATION

CLEANING INSTRUCTIONS

All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft 

cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc. which could adversely 

affect the finish and are not recommended for cleaning.

Do not use abrasive cleaners or solvents on Kohler faucets and fittings. 

INSTALLATION CHECKOUT

How to Install the Showerhead

Turn the diverter handle, run hot and cold water for one minute to remove any 

debris before the showerhead(27) is installed.

Put the regulator(28) into the showerhead inlet if needed. Connect the           

showerhead to the tube kit outlet with the washer(29), and tighten the            

showerhead with strap wrench. 

Hot

Cold

How to Install the Faucet

To perform installation, installer must provide G1/2

″ 

female supply 

fittings(1), spaced 150mm apart and horizontally. The supply fittings 

should be vertical and not beyond the finished wall. Hot supply pipe must 

be located on the left.

Flush the water supply pipes thoroughly to remove debris. Install the two 

offset connectors(2) into the hot and cold supply pipes. Use appropriate 

thread sealants or thread tape on pipe threads.

Adjust the center-to-center distance between the connectors to 150mm 

and horizontally. They should extend 29mm beyond the finished wall. 

Thread the escutcheons(3) onto the connectors until they are against the 

finished wall. 

Put the washers(4) into the nuts(5), thread the nuts to connectors. 

Tighten the nuts with strap wrench or soft cloth between product and 

regular wrench.

How to Install the Shower Column

Select a location in vertical wall to install shower column according to 

rough-in dimensions. Drill the lower hole according to anchors’(6)           

diameter and lower base(8-1) position in the finished wall(

NOTE:

 The 

arrow in the base is upward). Press anchors into the hole, secure the 

base by the screw(7). 

Rehearse the slide bar kit(9) installation for the upper base(8-2) mounting 

location determination. Slide the tube joint(10) onto the slide bar kit, and 

connect them to the base(

NOTE:

 The arrow in the base is up). Install the 

screws(12) into the tube joint with the hex wrench(11), and tighten them.

Place the slide bar and the body against the finished wall. Connect the 

lower base and the diverter body kit(13).  Position and tighten them by 

hex wrench. Mark the hole of upper base(8-2) with a pencil. Uninstall the 

slide bar kit and tube joint.(

NOTE:

 Don’t lose the screws.)

Drill holes on the mark. Press the anchors into the holes. Secure the 

upper base(8-2) by the screws. Install the tube joint(10) to the base(8-2) 

and tighten them by screws. Reinstall the slide bar kit with 

escutcheons(14) to the bases. Tighten the screws with the hex wrench. 

Screw the escutcheons with the bases until against the finished wall.

Install the tube kit(15) into the slide bar kit. Install the nut(16) onto the 

tube kit with soft cloth between internal hole of the nut and the tube kit. 

Then screw the nut onto the slide bar kit with strap wrench or soft cloth 

between the nut and regular wrench. 

2

1

150mm

6

7

12

8-2

14

6

7

12

8-1

14

13

16

15

10

11

9

How to Install the Handspray and Hose

Tighten 500mm length hose(18) to the outlet(19) and the connector(20) with two 

washers(17).

Turn the diverter handle(21), run hot and cold water for one minute to remove any 

debris.

Tighten 1500mm length hose(24) to the connector(23) with filter washers(22). Put 

the regulator(25) into the handspray(26) inlet if needed. Tighten the hose to the 

handspray with the filter washer(22).

29

28

27

5

4

29mm

3

22

25

26

24

19

17

20

21

22

23

17

18

Ensure that all connections are tight. Ensure that the handle is in the off position.

Turn on the drain and main water supply, and check for leaks. Repair as needed.

Remove the aerator(30) by coin. Run hot and cold water through the faucet for 

about one minute to remove any debris. Check for leaks. Remove any debris 

from the aerator.

Lift the diverter gently, turn clockwise for shower. Remove the hose(18). Run hot 

and cold water through faucet for about one minute to remove any debris. Shut 

off the faucet. Reinstall the aerator and hose.

30

18

Отзывы: