Operating fluids and maintenance
Operation and Maintenance Manual
Maintenance schedule — ESP 50Hz emission optimized top power
5.6.2 ESP 50Hz emission optimized top power — Service
level 2
SL204 Cylinder head
valves
1000
2
X
Check / set valve clearance.
SL225 Viscous damper
4000
X
Replace the viscous damper.
SL209 High pressure
pump
4000
10
X
Replace the HP pump.
SL215 Water pump
4000
X
Replace the water pump.
SL223 Battery charging
alternator
4000
X
Replace the battery charging alternator.
SL205 Injection
4500
X
Replace fuel lines and injectors.
SL213 Exhaust gas
turbocharger
4500
X
Replace the exhaust gas turbocharger.
SL219
-A
Exhaust gas
turbocharger
1
X
Replace the exhaust gas turbocharger rubber sleeve.
SL219
-B
Lines
4
X
X
Check and replace lines and hoses if necessary.
Tab. 23: ESP 50Hz emission optimized top power — Service level 2
52
© 2017 by Kohler Co. All rights reserved.
KD27V12 33521029401_3_1 en 2017-07-01