8. Install the Handle
IMPORTANT!
Correct alignment of the temperature override and
handle is critical.
Align the pin on the mounting hub in the 6 o’clock position.
Slide the temperature control into place with the adjustment
button in the 11 o’clock position.
Partially thread the handle into place while holding the
temperature control in place. To thread the handle into place hold
onto the handle and spin the bonnet clockwise.
Gently turn the temperature control clockwise until you hear
and/or feel the pin pop into the temperature control.
Thread the handle the rest of the way while making sure the
temperature control and pin remain engaged.
Push down on the button override and turn the temperature
control all the way to the hot side. If the arm turns past the hot
mark on the escutcheon, turn the temperature control the
opposite direction to the cold mark.
Turn on the water and check the maximum temperature.
Hole
Pin
Bonnet
Arm
Pin
Temperature Control
Handle
Button Override
11
O'clock
Position
Kohler Co.
13
1066047-2-C