Please contact with distributor or Kohler China Investment Co., Ltd., if the trouble remains after above-mentioned actions are taken.
拆下皂液器单向阀
(见图8)。
清洗后重新装回皂液器
长时间未添加和使用皂液或
皂液器管路堵塞
(
)
擦干感应窗口的残留水滴
TROUBLE SHOOTING
Symptoms
Probable Causes
Corrective Action
No soap dispensed
(Display on panel)
Soap used up
Replenish soap solution
No soap solution filled into dispenser for a long
time or clogged soap solution tube
Dismantle check valve on soap dispenser, clean
and reinstall back to the soap dispenser
(Fig
.
8)
Clean soap dispenser pipeline
Activate auto clean soap solution function
Improper soap dispenser connection
No manual soap solution extraction
performed after initial installation
Inspect soap dispenser wiring and hose
Press button on control box and manually extract
soap solution according to installation steps
Deactivated
(No display on panel, no
water and soap flows)
No power supply or incorrect wire
connection (AC)
Inspect general power and wiring condition
Other objects within sensing range
Dirty sensing window
Improper or wrong terminal connection engagement
Angle valve is closed
Filter device is blocked
Clogged foam soap cartridge
Remove objects
Clean window
Inspect terminal
Open valve
Clean filter
Clean foam cartridge
The stop valve is not open completely
The Aerator
is blocked
The filter is blocked
The supply water pressure is low
Open the angle valve
Clean
aerator
Clean filter
Check the water supply system
Low flow
Water runs for longer than
1 minute without switching
off
Object in sensing range
Remove object
Clean residual water on
the induction window
No water flows
(Panel display)
(
面板不点亮
,
不
出水和皂液
)
约1分钟内
不止水