 Tighten panel with flush valve with 4 pcs of long screws.

 

a. Put on clean gloves during installation to avoid surface 

 

 

  damage.

 

b. Do not face the side with letters inwards or install in 

 

 

  a reverse way.

USER’S GUIDE

NOTICE: 

The first 10 minutes with power is the standby time for adjusting sensing distance. Persons or subjects 

should avoid standing before the sensor. The sensor will not flush during this time.

Eco-friendly flush mode

: When the urinal is not used for a long term, it is set to flush with large volume 

of water automatically every 24 hours.

Set Working Status:

  The product comes our factory with:

1. The working status is set as dual-flush. If you want to cancel the first flushing function, place manual flush 

 

  stick adjacent to right side of sensing window for more than 1 second during the 10-minute standby period 

 

  (human presence in sensing range would cause the indicator to flash fast). The sensor would generate a 

 

  flushing cycle to indicate the setup of the sensor has been adjusted to after-use flushing. If the action is not 

 

  completed during this 10 minute, or you need to restore the working status to dual-flush, plug off the power 

 

  cord and reconnect the power supply until the indicator stops flashing and repeat the above procedures.
2. The diction time is set as 2s to avoid improper function in narrow toilets, the detection time is automatically set 

 

  from 2s to 5s.

Working Status:

 Before powering the system on, clear the unwanted objects in front of the sensor window 

lest shortening the sensing distance.

Sensing Distance: 

During the first 10 minutes, when powered on, the system is in the phase of automatic 

 

regulation, and no operation is required.

Deodorizing Flushing: 

The urinal will take a flush automatically when it’s used 3 or 4 times in 2 minutes.

Adjusting Screw

Hex Wrench

Long Screw M4 x 50

Flushing

 

Volume

: If you need to regulate the flushing 

 

volume, you can take off the cover and turn the adjusting 

screw in the center of the stop valve to a proper place.

Manual Flushing: 

Approach the supplied special 

 

magnetic stick (flushing control stick) to the middle part 

 

of the sensor lens. The system is now at manual status and 

 

the indicator will flash every 1 seconds. Approach the 

 

flushing control stick to the window,it’ll start to flush; 

 

approach again, stopping flushing.This status will last 

 

for 8 minutes until it turns to the normal working status. 

 

(The flushing, if any, will be terminated when this status ends).

NOTICE:

 The longest flusing time is 30 seconds once. If the 

 

flushing control stick keeps near to the sensing window, 

 

the manual status will be terminated automatically and 

 

reassume the normal working status.

Flushing control stick

Содержание K-8872X-C03

Страница 1: ...installation is finished 11 The head AC power supply must be protected with appropriate fuse 12 Please confirm the AC power supply and water supply should be shut off before maintaining the products with AC power related 13 All electrical connection must be compliance with related regulation and codes 14 All installation staff should be well familiar with installation instruction MINI มินิ URINAL ...

Страница 2: ...456 SP O Ring 1082073 SP Control Box Assy 1045460 SP Spring Fixed Cap 1045441 SP O Ring 1039038 SP Filter 1045444 SP Filter Bolt 1045445 SP O Ring Screw 1039036 SP Adjustment Bolt 1045451 SP O Ring 1045450 SP Gasket 1045449 SP Center Unit Assy O Ring Pressing Board 1045458 SP Valve Cover 1045461 SP Diaphragms Assy 1045462 SP Diaphragms Bracket Assy 1045459 SP O Ring Connection O Ring Valve Body Sc...

Страница 3: ...is not supplied in this package c To ensure an effective flush performance and urinal with corresponding flush volume is required And the urinal should comply with ASME A112 19 2 2003 Siphon urinal is not recommended d Used with urinals K 4904X ER 0 K 4986X ER 0 K 4991X ER 0 K 18645X Y 0 K 5016T YER 0 No need to prepare adapter beforehand for K 4904X ER 0 K 4986X ER 0 K 4991X ER 0 K 18645X Y 0 Ø55...

Страница 4: ... a Be careful not to use excessive force on bracket in order to avoid distortion when installing outlet pipe and bushing b After both ends of sensing window bushing are connected make it vertical with the wall and avoid deflection c For hose installation avoid over bended and distorted d Please clean the inside of water supply pipe before connecting to the product Bushing Slot AC Bushing Slot 52 7...

Страница 5: ... bracket assy with sensor panel assy according to the direction shown in the figure after loosening NOTE a Avoid sensor window panel falls off when taking apart fixing bracket from sensor window panel b Put on clean gloves during disassembly to avoid panel damage Sensor Panel Assy Sensor Panel Assy Fixing Bracket Assy Sensor Panel Key Active Plate of Fixing Bracket Fixing Bracket Assy 7 Loosen scr...

Страница 6: ...d tape CAUTION a Do not connect 220V AC power supply to DC wiring terminal b Do not damage the covering of AC power unit or remove screws to avoid leakage NOTE a Keep the connector away from water b Don t mistake the direction of inlet and outlet c Do not connect the DC output of AC power unit to AC power supply d Do not connect to power supply during installing process Connection line is not supp...

Страница 7: ... and repeat the above procedures 2 The diction time is set as 2s to avoid improper function in narrow toilets the detection time is automatically set from 2s to 5s Working Status Before powering the system on clear the unwanted objects in front of the sensor window lest shortening the sensing distance Sensing Distance During the first 10 minutes when powered on the system is in the phase of automa...

Страница 8: ...th a brush Battery indicating light keeps flashing and no flushing 1 Just power cut AC 1 Check the power supply MAINTENANCE Urinal Repair When repairing you don t have to dismount the sensor Cover the sensing window with tape and work with ease CAUTION Don t use very adhesive tape in case the scar will be hard to remove Care Cleaning Keep the sensor window clean wipe the soft cloth and mild cleane...

Страница 9: ... าให แสงแดดส องโดนเซ นเซอร 4 อย าแขวนวัตถุสะท อนแสงไว ตรงข ามกับเซ นเซอร หรือติดตั งเซ นเซอร แสง เซ นเซอร อิเล กทรอนิกส เช น ฟลัชวาล วเซ นเซอร 5 อย าติดตั งเซ นเซอร ใกล สนามแม เหล กไฟฟ าหรือแหล งก ำเนิดรังสีอัลตราไวโอเลต 6 ดูแลรักษาความสะอาดเซ นเซอร อยู เสมอ ท ำความสะอาดฝาครอบเซ นเซอร ด วยผ านุ มและสารท ำความสะอาดที มีฤทธิ อ อนๆ อย าใช ผงขัดหรือสารท ำความสะอาดที มีส วนผสมของน ำมัน สารที มีฤทธิ เป ...

Страница 10: ...รอบวาล ว 1045461 SP ชุดไดอะแฟรม 1045462 SP ชุดแผงยึดไดอะแฟรม 1045459 SP โอริง 1060674 SP ตัวลดแรงดันนํ า 1045448 SP สปริงชุดควบคุมกลาง กุญแจไขฟิลเตอร ประแจแอล แผงยึด แผงยึดฝาครอบ สกรู 1079274 SP เพลทยึด สกรู สกรู เพลทยึด 1082072 SP CP ฝาครอบเซ นเซอร 1082073 SP ชุดกล องควบคุม ข อต อ โอริง ตัวเรือนวาล ว สกรู นอต นอต กล องครอบวาล ว 1039036 SP โบลท ปรับอัตราการไหลของนํ า 1045444 SP โบลท ยึดฟิลเตอร 104...

Страница 11: ...งที ดี ควรเลือกใช โถปัสสาวะชายที มีปริมาณการใช น ำที เหมาะสม รวมถึงเลือกใช สุขภัณฑ ที ผลิต ตามมาตรฐาน ASME A112 19 2 2003 ไม ควรใช โถปัสสาวะชายที มีระบบช ำระล างแบบไซฟอน ง ใช ร วมกับโถปัสสาวะชาย K 4986X ER 0 K 4986X ER 0 K 4991X ER 0 K 18645X Y 0 K 5016T YER 0 ท านไม จ ำเป นต อง จัดเตรียมอะแดปเตอร เมื อใช ผลิตภัณฑ รุ น K 4986X ER 0 K 4986X ER 0 K 4991X ER 0 K 18645X Y 0 ขนาดระยะแสดงค าโดยประมาณ หน...

Страница 12: ...ัง ค อย าหักงอสายน ำดี ง ท ำความสะอาดท อน ำดีก อนเชื อมต อผลิตภัณฑ ช องสําหรับ ปลอกหุ มสายไฟ ช องสําหรับ ปลอกหุ มสายไฟ 52 75 ช องสําหรับ ท อนํ าเข า 52 ตําแหน งติดตั งฟลัชวาล ว 140 80 ช องสําหรับท อนํ าออก ความลึกของช อง อย างน อย 100 มม เลนส เซ นเซอร ตําแหน งติดตั งฝาครอบเซ นเซอร 100 400 100 80 41 55 180 75 27 เส นผ าศูนย กลางด านนอกของ ปลอกหุ มสายไฟไม เกิน 32 มม เส นผ าศูนย กลาง ด านนอกของปลอกหุ...

Страница 13: ... ปลอกหุ มสายไฟเซ นเซอร ท อนํ าเข า และท อนํ าออกจากนั นจึงปูกระเบื อง 6 ถอดฝาครอบเซ นเซอร และชุดแผงยึด คลายสายรับส งสัญญาณที พันอยู รอบชุดแผงยึด หมุนแผ นเพลทบนแผงยึดตามเข มนาฬิกา โดยใช กุญแจไขฝาครอบเซ นเซอร ดังภาพแสดง ถอดแยกฝาครอบ เซ นเซอร ออกจากชุดแผงยึดดังภาพแสดง ข อสังเกต ก อย าท ำฝาครอบเซ นเซอร ตกเมื อถอดแผงยึดออกจากฝา ครอบเซ นเซอร ข สวมถุงมือก อนถอดแยกชิ นส วนเพื อป องกันไม ให ฝาครอบ ได รับคว...

Страница 14: ...หล งจ ายไฟ AC 220 โวลต ข อย าให ฝาครอบแหล งจ ายไฟ AC ได รับความเสียหายหรือถอดสกรูยึดฝาครอบออก ไม เช นนั นอาจเกิดไฟฟ ารั วได ข อสังเกต ก ติดตั งขั วต อให ห างจากน ำ ข ตรวจสอบทิศทางของท อน ำเข าและท อน ำออกให ถูกต อง ค อย าต อขั วต อสายไฟ DC เข ากับแหล งจ ายไฟ AC ง อย าต อแหล งจ ายไฟระหว างขั นตอนการติดตั งเมื อเชื อมต อสายไฟขอแนะน ำให ใช สายไฟACที หุ มฉนวนพื นที หน าตัดของสายไฟ AC ต องไม น อยกว า 0...

Страница 15: ...ั นท ำซ ำขั นตอนการปรับตั งที อธิบายไว ข างต น 2 ระยะเวลาทดสอบอยู ที 2 5 วินาที สถานะการท ำงาน น ำวัตถุที วางอยู หน าเซ นเซอร ออกก อนเปิดเครื อง ระยะการตรวจจับ เมื อเปิดเครื อง ในช วง 10 นาทีแรกเซ นเซอร จะปรับระยะการตรวจจับอัตโนมัติ การช ำระล างแบบก ำจัดกลิ น โถปัสสาวะชายจะช ำระล างอัตโนมัติเมื อมีการใช งาน 3 ถึง 4 ครั งใน 2 นาที สกรูปรับ ประแจแอล สกรูยาวขนาด M4 x 50 ปริมาณน ำ หากต องการปรับปริมาณ...

Страница 16: ...ึง ประกอบกลับเข าที ข อพึงระวัง ปิดวาล วน ำ หรือขันโบลท ปรับอัตราการไหลของนํ าให แน นก อนท ำความสะอาด 1045442 ฟิลเตอร 1045440 ฝาปิด 1021430 กุญแจถอดฟิลเตอร การแก ปัญหาเบื องต น อาการ สาเหตุที เป นไปได การแก ปัญหา ผลิตภัณฑ ไม ช ำระล าง ไฟแสดงไม กะพริบ 1 ไม ได ต อสายไฟหรือต อสายไฟไม ถูกต อง 2 มีกระจกหรือวัตถุสะท อนแสงประเภทอื นๆ อยู ใน ระยะการตรวจจับ 3 ต องท ำความสะอาดเซ นเซอร 1 ตรวจสอบการเชื อมต อส...

Отзывы: