2. Fix the power cord to the bathroom heater

(1) Remove the screw on the wiring cover plate.
(2) Open the wiring cover plate.
(3) Lift the terminal protection cover.
(4) Loosen the screw fixing the power cord clip.
(5) Loosen the screw on the wiring terminal, insert the

power cord (not supplied) connected to the indoor fixed
line into the wiring terminal, tighten the wring terminal
screw.

(6) Fix the power cord with power cord clips. (The power

cord clip must pin the insulation sheath of power cord.)

(7) Use the screw removed in step (3) to fix the wiring

cover plate again.

2.

(1)
(2)
(3)
(4)
(5)

(

)

(6)

(

)

(7)

(3)

Power cord

L

N

Wiring Terminal

3. Installing the Main Body Method 1 integrated ceiling.

integrated ceiling should be 300*300, 300*450, 300*600

(1) Disassembly the decorated plate around the position of

the product installation.

3.

300*300

300*450

300*600

(1)

(

)

300mm*300mm integrated ceiling

300mm*300mm

Disassembly 6 pieces

6

Disassembly 6 pieces

6

300mm*450mm integrated ceiling

300mm*450mm

300mm*600mm integrated ceiling

300mm*600mm

Disassembly 3 pieces

3

-7-

(2) Use the install template as the diagram to insert it into

the ceiling to mark the position of the drill.

(2)

90

300mm*300mm integrated ceiling

300mm*300mm

Bending line

Install Template

Install Template

Install Template

Install Template

Install Template

Cement Board

Cement Board

Ceiling

Drill Position

600
465

200

300

Bottom view

1290505-T01-C

Содержание K-77283T-MZ

Страница 1: ...Guide Underscore Bathroom Heater S450 S450 K 77315T MZ Air care K 77315T X MZ Cloud K 77283T MZ KOHLER CHINA INVESTMENT CO LTD NO 158 JIANG CHANG SAN ROAD JING AN DISTRICT SHANGHAI PRC POST CODE 2004...

Страница 2: ...ies with GB 4706 1 2005 GB4706 23 2007 and GB 4706 27 2008 please leave instructions for the consumer GB 4706 1 2005 GB4706 23 2007 GB 4706 27 2008 WARNING Risk of electrical shock WARNING Risk of ele...

Страница 3: ...ir Exhaust Pipe Clamp Air Outlet Window Keel M6 Nut M6 6 6 Spring Washer 6Washer 6 BTP4 8 Triangular Self Tapping Screw BTP4 8 Note Plaster or other ceiling opening dimension 450 X 290 mm 450 X 290 mm...

Страница 4: ...MOTOR HOT MOTOR CAPACITOR CAPACITOR CAPACITOR CAPACITOR ALL POLE SWITCH OPTIONAL ALL POLE SWITCH OPTIONAL 220V 50Hz 220V 50Hz CN4 CN4 CN7 CN7 CN8 CN8 CN5 CN5 CN6 CN6 CN2 CN2 CN3 CN3 CN9 CN9 CN13 CN1 C...

Страница 5: ...Outlet window installation Fix the air exhaust pipe to the outlet window on the wall with the clamp as the preparation of bathroom heater installation Seal the pipe and the outlet window with foaming...

Страница 6: ...mm 275mm 1300mm 270mm C Packing List C 5 1285554 Decorated Plate X2 X2 1285555 Remote Control Only K 77315T MZ K 77315T X MZ K 77315T MZ K 77315T X MZ 1285542 Install Template 1285550 Ventilation Outl...

Страница 7: ...0mm or above The power cord to the product shall have enough length for the installation The distance between the product and the air outlet window shall be 1000mm or lower Cut the screw rod M6 to sui...

Страница 8: ...N Wiring Terminal 3 Installing the Main Body Method 1 integrated ceiling integrated ceiling should be 300 300 300 450 300 600 1 Disassembly the decorated plate around the position of the product inst...

Страница 9: ...by 8 BTP4 8 screw 3 M6 4 8 BTP4 8 M6 Butterfly Nut M6 6 Washer 6 6 Spring Washer 6 M6 Nut M6 M6 Nut M6 BTP4 8 Triangular Self Tapping Screw BTP4 8 8 Suspender Cement Board Ceiling Surface Install temp...

Страница 10: ...t Taper 1 100 1 50 BTP4 8 Triangular Self Tapping Screw BTP4 8 1 80 Ventilation Outlet Assy 80 Ventilation Outlet Assy Clamp Air Exhaust Pipe 80mm 7 Install the decorated plate and adjust the nut on t...

Страница 11: ...ing position of the suspender as shown by the install template 2 Cement Board Suspender 10 2 Fix the ventilation outlet assy to the main body using the BTP4 8 self tapping screw 3 Fix the suspension b...

Страница 12: ...e to install the remote controller shall not be easily splashed by water Choose a mounting location for the remote holder Drilling two holes with depth larger than 45mm on the wall by drill with a dia...

Страница 13: ...mer down UP Timer up HEATER Turn on the heater mode FAN Turn on the fan mode DRY Turn on the hot cool dry clothes mode VENTILATION Turn on the ventilation long time vent mode 24 AIR FLOW Set the air f...

Страница 14: ...ours the setting time cannot be changed E 6 10 6 6 10 6 6 10 6 6 10 6 2 10 2 24 24 TROUBLESHOOTING Problem Diagnosis Solution Bathroom Heater does not work The remote controller does not display The r...

Страница 15: ...Do not use eradicator abrasive powder or oil acid or alkali liquid detergent to clean casing or air louver 3 Never try to put a small screw driver or any other object into the holes of air Louver fro...

Страница 16: ...not easy to be affected by damp 3 The head AC power supply must be protected with appropriate fuse 4 Please confirm the AC power supply should be shut off before maintaining the products with AC powe...

Отзывы: