1025493-2-
A
Kohler Co.
8
Disc
Indexer
Handle
Setscrew
Bonnet
Stop
Tab
Mounting
Nut
Splines
Valve Stem
9. Adjust the Temperature Setting
NOTE
:
Prior to adjustment, make sure the handle is in the
maximum hot position.
-
If desired, adjust the maximum hot water temperature setting of this
faucet.
-
Remove the setscrew, handle, and bonnet. Push the valve stem up
and turn it fully clockwise to obtain maximum water temperature.
-
Mark the current position of the temperature stop tab (top edge) on
the mounting nut with a marker. Lift the indexer and the disc just
enough to clear the splines and allow rotation.
NOTE
:
Each spline notch is an average 9.5
_
F (5.3
_
C) change in
temperature.
-
Turn the indexer, disc, and valve stem counterclockwise until the
desired temperature is achieved. When desired temperature is
achieved, reinstall the indexer and top disc to the valve, making sure
the top disc is snapped fully into the indexer.
-
Turn off the water by pulling the valve stem down. Reinstall the
bonnet, handle, and setscrew.