![Kohler K-45600X Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/kohler/k-45600x/k-45600x_installation-and-care-manual_1987825006.webp)
1198675-X2-A
6
Kohler Co.
¨
Connect the drain to the trap.
¨
Run water into the bath, and check the drain connections for leakage.
¨
Install the faucet valving according to the faucet manufacturer‘s instructions. Do not install the faucet trim
until instructed. Open the hot and cold water supplies, and check the supply connections for leakage.
¨
Ensure a seal on the bath drain and the floor drain.
NOTE:
An access panel will simplify future maintenance.
C. Make Electrical Connections
NOTE:
Electronic parameter label located on the controller. This label also identifies the electrical rating.
¨
Your Kohler bath with airjets is equipped with a cord and plug. The blower motor has been wired at the
factory. A licensed electrician must install a dedicated GFCI-protected or Earth-Leakage Circuit-Breaker
(ELCB), 220 V, 10 A, grounded outlet.
¨
Plug the control box into this outlet.
¨
Clean the area of all dust and debris.
D. Test Run the Bath with Airjets
¨
Check all electrical connections, and make sure the electrical power to the bath with airjets is on.
¨
Make sure all piping connections in the air harness are secure.
¨
Verify that the blower motor is secure.
¨
Temporarily remove the plastic drop cloth or other protective sheeting from the bath.
¨
Slide the sliding slip to unlock the panel. Touch the electronic drain on/off button “
“ to close the drain.
The pink light flashes. Fill the bath to a level at least 10 cm above the top of the highest airjet.
¨
Refer to “Bath Operation” to make sure that every function works well.
¨
Check the drain piping for leaks. Repair any leaks.
¨
Operate the bath and check for air flow through the airjets. Check the air piping for air leaks.
¨
Stop the bubble massage and drain the water.
¨
Return the plastic drop cloth or other protective sheeting to the bath. Check the drain connections for leakage.
B. Install the Plumbing
CAUTION:
Risk of product damage.
Ensure a watertight seal on the bath drain.
WARNING: Risk of electric shock.
To reduce the risk of electrical shock, connect the control box to
a properly grounded, grounding-type receptacle protected by Ground-Fault Circuit-Interrupter (GFCI) or
Earth-Leakage Circuit-Breaker (ELCB). Do not remove the plug grounding pins.
Install the Bath (Cont.)
Drain
Drain Pipe
Seal on the bath
Floor
38
c
o
-
+
Manual Purge
Electronic Drain On/Off
Pump On/Off
Water Temperature
Decreases/Increases Flow
Содержание K-45600X
Страница 1: ...Installation and Care Guide BubbleMassage Bath 1198675 X2 A 2013 Kohler Co K 45600X K 45602X K 45604X...
Страница 14: ...GFCI ELCB 1198675 X2 A 14 Kohler Co...
Страница 15: ...Kohler Co 15 1198675 X2 A GFCI ELCB 220 240 10 50...
Страница 16: ...1198675 X2 A 16 Kohler Co 1 390 5 15 0 4 2 5 2 2...
Страница 17: ...Kohler Co 17 1198675 X2 A drywall 50 2...
Страница 18: ...1198675 X2 A 18 Kohler Co GFCI ELCB GFCI ELCB 220 10 10 38 c o...
Страница 19: ...Kohler Co 19 1198675 X2 A 600 12 6 x 1800 12 x 900...
Страница 20: ...1198675 X2 A 20 Kohler Co 38 c o 1 3 30 1 20 2 20 2...
Страница 21: ...Kohler Co 21 1198675 X2 A 38 c o 38 c o 38 c o 38 c o 1 2 4 3 50...
Страница 22: ...1198675 X2 A 22 Kohler Co 38 c o 38 c o 38 c o 5 7 6 50 50 50...
Страница 23: ...Kohler Co 23 1198675 X2 A 2 20 1 2...
Страница 24: ...1198675 X2 A 24 Kohler Co 1 GFCI ELCB 2 3 20 GFCI ELCB GFCI ELCB 4 20 5 6 7...
Страница 25: ...Kohler Co 25 1198675 X2 A 8 9 10 11 12 13 1 mirror glaze 28 metal polish Green Oil...
Страница 26: ...1198675 X2 A 26 Kohler Co 10 60 Soda Acid...
Страница 27: ...Kohler Co 27 1198675 X2 A...