2. Fix the power cord to the bathroom heater
(1) Remove the screw on the wiring cover plate.
(2) Open the wiring cover plate.
(3) Lift the terminal protection cover.
(4) Loosen the screw fixing the power cord clip.
(5) Loosen the screw on the wiring terminal, insert the
power cord (not supplied) connected to the indoor fixed
line into the wiring terminal, tighten the wring terminal
screw.
(6) Fix the power cord with power cord clips. (The power
cord clip must pin the insulation sheath of power cord.)
(7) Use the screw removed in step (1) to fix the wiring
cover plate again.
2.
(1)
(2)
(3)
(4)
(5)
(
)
(6)
(
)
(7)
(1)
3. Installing the Main Body Method 1 integrated ceiling.
integrated ceiling should be 300*300, 300*450, 300*600
(1) Disassembly the decorated plate around the position of
the product installation.
3.
300*300
300*450
300*600
(1)
(
)
300mm*300mm integrated ceiling
300mm*300mm
Disassembly 6 pieces
6
Disassembly 6 pieces
6
300mm*450mm integrated ceiling
300mm*450mm
300mm*600mm integrated ceiling
300mm*600mm
Disassembly 3 pieces
3
-6-
(2) Bend the installation template to 90 at the bending line.
Push the template to the location of fixed hole A in the
ceiling as the diagram shows.
°
(2)
90
A
(
)
300mm*300mm integrated ceiling
300mm*300mm
Power cord
L
N
Wiring Terminal
Bending Line
Install Template
Install Template
Install Template
Install Template
Fixed Hole A
A
Cement Board
150
288
1374353-T01-A