Troubleshooting (cont.)
Symptoms
Probable Causes
Recommended Action
3.
Error 0104 is displayed.
A.
Temperature sensor not
connected.
A.
Connect the temperature sensor.
B.
Temperature sensor is damaged.
B.
Call the Customer Care Center
using the information provided on
the back page of this manual.
4.
Error 0408 is displayed.
A.
A communication error has
occurred.
A.
Perform a system reset on the user
interface.
5.
Lights on the adapter are
off.
A.
Inadequate power is supplied to
the generator (green status light
on generator is off).
A.
Provide proper power to the
generator. If necessary use the
provided test kit to ensure the
generator is working properly.
B.
The user interface is not
receiving power from the
generator (green status light on
the generator is on).
B.
Use the provided test kit and
instructions to identify the source
of the problem.
C.
The user interface is damaged
(green status light on the
generator is on).
C.
Call the Customer Care Center
using the information provided on
the back page of this manual.
6.
″
GEN TEST
″
light is
blinking red.
A.
An error has occurred with the
steam generator.
A.
Check the error code on the user
interface. See the corresponding
error code in this document.
7.
″
TEMP SENSOR
″
light is
blinking red.
A.
The temperature sensor is not
connected.
A.
Connect the temperature sensor.
B.
The temperature sensor is
damaged.
B.
Call the Customer Care Center
using the information provided on
the back page of this manual.
8.
″
DATA LINK
″
light is
blinking red.
A.
A connection to the media
module has not yet been
established.
A.
Wait for the connection to be made.
B.
A connection to the media
module cannot be established.
B.
Remove and reattach the cable that
connects the adapter to the media
module. Inspect cable for damage
and replace if necessary.
C.
An error has occurred.
C1.
Check the error code on the user
interface. See the corresponding
error code in this document.
C2.
Reset power to the generator and
media module.
C3.
Perform a system reset on the user
interface.
9.
Steam menu disappears
after requesting steam.
A.
Cables between the generator(s)
and adapter are installed
incorrectly.
A1.
Reinstall the black and/or silver
cable(s) between the steam
generator(s) and adapter per the
instructions in the installation
guide.
A2.
Call the Customer Care Center
using the information provided on
the back page of this manual.
10.
Display does not show
steam function.
A.
Inadequate power is supplied to
the generator (green status light
on generator is off).
A1.
Provide proper power to the
generator. Use the provided test kit,
if necessary, to ensure the generator
is working properly.
A2.
Call the Customer Care Center
using the information provided on
the back page of this manual.
Kohler Co.
5
1069332-5-C
Содержание K-1737
Страница 22: ...1069332 5 C ...
Страница 23: ...1069332 5 C ...
Страница 24: ...USA Canada 1 800 4KOHLER México 001 800 456 4537 kohler com 2010 Kohler Co 1069332 5 C ...