2. Complete the Installation
Position the wall support tube in the wall bracket, and connect
the compression fittings with the fiber washers in place.
Tighten the plated nuts, but do not overtighten.
Secure the wall support tube to the wall bracket with two
square-head setscrews.
Install the lavatory or sink supply.
Turn on the water supply.
Open the supply stops with the key and check for leaks. Repair
as needed.
Adjust the maximum temperature setting by turning the regulator
pin on the top of the control fitting. Turn the pin
clockwise to
reduce
and
counterclockwise to increase
the maximum water
temperature.
Install lavatory or
sink supply.
Square-Head
Setscrew
Compression
Fitting
Compression
Fitting
Fiber Washer
Supply
Stop
Plated
Nut
Wall Support
Tube
Wall Bracket
Turn Pin to Adjust
Maximum Water
Temperature
Kohler Co.
5
105334-2-AB