background image

Product Information

Applicable product:
Drop-in rim style, custom pump

K-1201-CB

Fixture*:
Bathing well:
Basin area, bottom

42

(1067 mm) x 17

(432 mm)

Basin area, top

55

(1397 mm) x 25

(635 mm)

Weight

93 lbs (42.2 kg)

To overflow:
Water depth

12-1/8

(308 mm)

Capacity

50 gal (189.3 L)

* Approximate measurements for comparison only.

Drop-in cut-out

58-1/2

(1486 mm) x 40-1/2

(1029 mm)

Pump:

V

Hz

A

1-speed

120

60

7.5

Minimum access panel

pump/control (required):

20

(508 mm) W x

15

(381 mm) H

Required Electrical Service

Dedicated circuit required, protected with a Class A

Ground-Fault Circuit-Interrupter (GFCI):
Pump/control

120 V, 15 A, 60 Hz

Locate the outlet behind the whirlpool and within 24

(610

mm) of the pump.

Notes

Install this product according to the installation guide.
Floor support under this product must provide for a minimum of

43 lbs/square foot (209 kg/square meter) loading.
The apron must be installed before the finished floor and wall

materials are installed.
Pump must be relocated to custom position at the time of

installation. Provide adequate clearance.
This fixture conforms to ANSI Standard Z124.1.2. All dimensions

are nominal.

No change in measurements if connected with drain
illustrated. (K-7161-AF or K-7161M-AF)

Pump/Control Access
20" (508 mm) W x 
15" (381 mm) H

30" (762 mm)

1-1/2"
(38 mm)

Ø 1-1/2"

17"
(432 mm)

8-1/2" (216 mm)

15"
(381 mm)

1-1/2"
(38 mm)

2-3/4"
(70 mm)

3" (76 mm)

2-7/8" 
(73 mm)

60" (1524 mm)

7-1/2" 
(191 mm) Max

3/16" (5 mm)

1013055-1-D

2

Kohler Co.

Содержание K-1201-CB

Страница 1: ...ct numbers are for Mexico i e K 12345M Los números de productos seguidos de M corresponden a México Ej K 12345M Français page 3 Español página 4 USA Canada 1 800 4KOHLER México 001 800 456 4537 kohler com K 1201 CB 1013055 1 D 2011 Kohler Co ...

Страница 2: ... Locate the outlet behind the whirlpool and within 24 610 mm of the pump Notes Install this product according to the installation guide Floor support under this product must provide for a minimum of 43 lbs square foot 209 kg square meter loading The apron must be installed before the finished floor and wall materials are installed Pump must be relocated to custom position at the time of installati...

Страница 3: ...commande 120 V 15 A 60 Hz Localiser la prise de courant derrière la baignoire à hydromassage à moins de 24 610 mm de la pompe Remarques Installer ce produit selon le guide d installation Le support du sol sous ce produit doit pouvoir soutenir une charge minimale de 43 lbs pied carré 209 kg mètre carré Le bandeau doit être installé avant d installer le sol fini et les matériaux du mur La pompe doit...

Страница 4: ... control 120 V 15 A 60 Hz Coloque el tomacorriente detrás de la bañera de hidromasaje y a menos de 24 610 mm de la bomba Notas Instale este producto conforme a la guía de instalación El soporte del piso debajo de este producto debe poder soportar una carga mínima de 43 lbs pie cuadrado 209 kg metro cuadrado El faldón debe instalarse antes que los materiales de acabado del piso y la pared Al instal...

Отзывы: