background image

   

                                                                          

1240258-2A-A          

                                                                                                                                          2  

  

   

                                                                          

1240258-2A-A           

                                                                                                                                         3

  

INSTALLATION

1. How To Install The Faucet

To perform installation, installer must provide G1/2

˝ 

female supply fittings(1), spaced 

150mm apart and horizontally. The supply fittings should be vertical and not beyond the 

finished wall. Hot supply pipe must be located on the left.

Flush the water supply pipes thoroughly to remove debris. Install the two offset 

connectors(2) into the hot and cold supply pipes. Use appropriate thread sealants or thread 

tape on pipe threads.

Adjust the center-to-center distance between the connectors to 150mm and horizontally. 

Thread the escutcheons(3) onto the connectors until they are against the finished wall. 

Put the washers(4) into the nuts(5), thread the nuts to connectors. Tighten the nuts with 

strap wrench or soft cloth between product and regular wrench.

CLEANING INSTRUCTIONS

All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft cloth. 

Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc. which could adversely affect the 

finish and are not recommended for cleaning.
Do not use abrasive cleaners or solvents on Kohler faucets and fittings. 

2. How To Install The Shower Column

Select a location in vertical wall to install shower column 

according to rough-in dimensions.

Drill the lower hole as anchors(6) diameter and lower base(8-1) 

position in the finished wall (

NOTE:

 The arrow in the base is 

upward). Press anchors into the hole, secure the base by the 

screws(7). 

Rehearse the slide bar kit(9) installation for the upper base(8-2) 

mounting location determination. Slide the tube joint(10) onto 

the slide bar kit, and connect them to the base(

NOTE:

 The 

arrow in the base is up). Install the screws(12) into the tube 

joint with the hex wrench(11), and tighten them.

Place the slide bar and the body 

against the finished wall. Connect 

the lower base and the diverter body 

kit(13). Position and tighten them by

hex wrench. Mark the hole of upper 

base(8-2) with a pencil. Uninstall 

the slide bar kit and tube joint.

(

NOTE:

 Don’t lose the screws.)

Drill holes on the mark. Press the 

anchors into the holes. Secure the 

upper base(8-2) by the screws. 

Install the tube joint(10) to the 

base(8-2) and tighten them by 

screws. Reinstall the slide bar kit 

with escutcheons(14) to the bases. 

Tighten the screws with the hex 

wrench. Screw the escutcheons 

with the bases until against the 

finished wall.

Install the tube kit(15) into the slide 

bar kit. Install the nut(16) onto the 

tube kit with soft cloth between 

internal hole of the nut and the tube

kit. Then screw the nut onto the slide

bar kit with strap wrench or soft cloth 

between the nut and regular wrench.

3. How To Install The Handspray & Hose

Remove the guards on the outlet connectors of 500mm 

length hose(18). Connect the outlet(17) to the connector

(19) with the hose(18), and tighten.

Turn the diverter handle(20), run hot and cold water for 

about one minute to remove any debris.

Remove the guards on the outlet connectors of 1500mm 

length hose(21). Tighten the shorter connector(21-1) of 

the hose(21) to the connector(22). Put the restrictor(23) 

into the handspray(24) inlet if needed. Tighten the 

handspray to the longer connector(21-2) of the hose. 

Ensure that all connections are tight. Ensure that the handles are in the off position. 

Turn on the drain and main water supply, and check for leaks. Repair as needed.

INSTALLATION CHECKOUT

4. How To Install The Showerhead

Turn the diverter handle to 

showerhead(25) work, run hot 

and cold water for about one 

minute to remove any debris 

before the showerhead is installed.

Before installation, put the 

regulator(26) into the showerhead 

inlet if needed. Take out the 

washer(27) and install the regulator 

as shown, reinstall the washer. 

Tighten the showerhead onto the 

tube kit outlet(28) with strap wrench. 

OPERATION INSTRUCTIONS

CARE AND MAINTENANCE

Turn the diverter handle of the column counter-clockwise, handspray works; turn it 

clockwise, showerhead works. 

The temperature is set by slowly turning the temperature selector(right-hand handle). 

For safety reasons, there is a stop that limits temperature to 40ºC. To get a higher 

temperature, push the button and continue turning the temperature selector. 

Water flow is set by turning the left-hand handle. There is also a water-saving stop. 

To obtain a higher flow rate, push the button and continue turning it.

Verification And Setting

Make sure that the water feeds of the faucet have reach their highest temperature 

by letting the water run sufficiently. With the selector in position 37ºC, the temperature 

of the water coming out of the faucet must be within a range of 36ºC and 38ºC, as 

measured by a thermometer. If this is not the case, the installer can adjust the setting. 

Proceed with the setting as follows: With the faucet on “cold” normal water flow, slowly 

turn the temperature selector(always in the same direction) until water at 37ºC is 

obtained. If the temperature goes over 38ºC, go back to the “cold” setting and set again. 

When the temperature is stabilized, without turning the temperature selector, unscrew 

the screw located on the top of handle with screwdriver. Install the handle with aligning  

the 37ºC with the mark “O” on the handle. Tighten the screw with the screwdriver.

2

1

150mm

4

Hot

Cold

3

2

5

6

7

12

8-2

14

6

7

12

8-1

14

13

10

11

9

15

16

21

18

17

23

24

21-2

21-1

19

20

22

31

29

33

30

32

The filters(29) protecting the faucet device may get obstructed and reduce water flow. 

When this happens, unscrew the bushes(31, left thread) by a wrench(30, 12mm) and 

take out the nuts(32), filters(29) and the check valves(33) after removing the faucet. 

Clean the filters by soaking them in warm vinegar. Reinstall them as the figure. 

Very hard water can obstruct the filters protecting the thermostatic cartridge and 

reduce the flow of water. Clean the filters by soaking the thermostatic cartridge in hot 

vinegar and follow the instructions in the figures on removing and installing the 

cartridge(The 37 mark is aligned with the mark on the body before removing). Adjust 

temp. as per the steps of verification and setting.

NOTE: 

Do not turn the temperature selector before reinstall it. Reinstall the 

temperature selector by aligning the 37 mark with the mark on the body.

25

26

27

28