4 — PROGRAM MENU PARAMETERS
pg. 25
Curtis Model 3150R – Oct. 2022
BDI MENU
The following table describes the parameters on the BDI menu.
Note: The BDI menu contains the BDI Setup menu.
BDI MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES
DATA SIZE
ACCESS LEVEL
DEFAULT VALUE
DESCRIPTION
Nominal Voltage
0x6555:00
Enumerated
0–3
32-bit
OEM Dealer
24V
Specifies the battery’s nominal voltage:
0 = 12V
1 = 24V
2 = 36V
3 = 48V
BDI Source
0x6709:01
Enumerated
0–2
32-bit
OEM Dealer
3150
Specifies the data source for the BDI data:
0 = 3150
1 = CAN
2 = SCI (serial)
Lift Lockout
0x6408:00
0.0–20.0%
0–200
32-bit
OEM Dealer
10.0%
Specifies the BDI percentage below which lift lockout
and the low BDI alarm are activated and the
is red.
BDI Low Alarm
0x640A:00
0–50.0%
0–500
32-bit
OEM Dealer
20.0%
Specifies the BDI percentage below which the low
BDI alarm is activated. When the BDI percentage is
below BDI Low Alarm and greater than or equal to
Lift Lockout, the BDI icon is yellow.