4 — PROGRAM MENU PARAMETERS
pg. 21
Curtis Model 3150R – Oct. 2022
SET HOURMETERS MENU
The following table describes the parameters for configuring the hour meter.
SET HOURMETERS MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES
DATA SIZE
ACCESS LEVEL
DEFAULT VALUE
DESCRIPTION
Hourmeter Source
0x6709:00
Enumerated
0–2
32-bit
OEM Dealer
3150
Specifies the data source for the hour meter:
0 = 3150
1 = CAN
2 = SCI
Reset KSI Hourmeter
0x6451:00
Off/On
0–1
32-bit
OEM Dealer
Off
Resets the 3150R’s keyswitch hour meter.
Set KSI Hourmeter
0x6414:00
0–99999.9 hours
0-999999
32-bit
OEM Dealer
0.0 hr
Specifies the time indicated by the 3150R’s
keyswitch hour meter.
CAN MENU
The following table describes the parameters on the CAN menu.
Note: The CAN menu also contains the RPDO 1–4 Byte Map and TPDO 1–4 Byte Map menus, which
specify the objects for which the PDOs transmit and receive data.
CAN MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES
DATA SIZE
ACCESS LEVEL
DEFAULT VALUE
DESCRIPTION
CAN Node ID
0x2000:01
1–127
1–127
32-bit
OEM Dealer
46
Specifies the device’s node ID.
CAN Baud Rate
0x2001:01
–1 to 4
–1 to 4
32-bit
OEM Dealer
0
Specifies the baud rate:
–1 = 100 Kbps
0 = 125 Kbps
1 = 250 Kbps
2 = 500 Kbps
3 = 800 Kbps
4 = 1 Mbps
Auto Operation
0x6557:00
0–1
0–1
32-bit
OEM Dealer
1
Specifies the NMT state when the device powers up:
0 = Pre-operational
1 = Operational
Message Center Node ID
0x7022:00
1–127
1–127
32-bit
OEM Dealer
80
Specifies the node ID for the message center.