22. Install the Door Handles
Fit the gasket over the groove in the side of the door panel.
Press the handle over the gasket so the clamp and screws are on the inside.
Thread in one or two screws to temporarily hold the handle in place. Note that the handle
protrusion fits into the groove in the glass panel.
Loosen the six handle clamp screws.
Slide the handle up or down so the bumper flat rests on the footbath curb.
Tighten all six screws carefully to avoid stripping them.
Repeat this procedure for the other handle.
23. Adjust the Stop Blocks
NOTE:
This step is critical to prevent the side door panels from accidentally slamming against one
another.
With all the doors closed, open the left side door.
Slide the loose stop block up against the exposed center door roller.
Close the left side door so it rests against the side jamb seal.
Slowly open the right side door until it nearly touches the left side door. A 1/4
″
(6 mm) gap
between the side door panel edges is sufficient.
Open the left side door to expose the stop block. Carefully secure the stop block in place by
tightening the stop block setscrew.
Repeat this procedure for the other stop block.
Gasket
Handle
Handle
Clamp
Screws
Handle
Clamp
Bumper Flat
Side Door Panel
Header
Roller
Stop Block
Inside
Track
Stop Block
Setscrew
Center Door Panel
Kohler Co.
19
1032118-2-D