INSTALLATION

How To Install The York

Do not take off guards(1) at this moment.

Determine where the york(2) will be located on the wall according to the 

lavatory. 

Connect the G1/2˝ supplies to the york. Please note that the side of the york 

with red dot connects to the hot supply and towards right. The distance between 

finished wall and supplies should be 47~57mm. Ensure that the gaps between 

guards and finished wall are less than 5mm.

Increase hot and cold water supply pressures to 1MPa. Inspect for leaks.

NOTE: 

Make sure two guards are the same distance to the wall. Ensure the 

centerlines of them are horizontal.

COLD

HOT

INSTALLATION CHECKOUT

Ensure that all connections are tight. Ensure that the handle is in the off 

position. 

Turn on the  main water supply, and check for leaks. Repair as 

needed.

CLEANING INSTRUCTIONS

CARE AND MAINTENANCE

All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft 

cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc, which could adversely 

affect the finish and are not recommended for cleaning.

Do not use abrasive cleaners or solvents on Kohler faucets and fittings. 

Clean Rectifier and Aerator

If there is a lot of debris in the supply pipes or the quality of water is bad, it will

cause the flow in bad condition. Please clean the filter and aerator as following 

steps:

Turn off the faucet. Take out the plugs(15). Remove the screws(17) with hex 

wrench(16). Uninstall the spout(18) from body(4). Remove the insert(19) and 

rectifier(20). Remove the aerator(22) by tool(21).

Flush the filter of rectifier and aerator. Check the filter and aerator whether is 

intact, if damaged replace it.

Reassemble the spout and body: put the insert, rectifier and aerator into the 

original position. Install the spout onto body and tighten the screws. Insert the 

plugs.

1

2

2

1

47~57mm

5mm Max.

18

17

16

4

19

20

22

21

15

How To Install The Faucet

When the finished wall is completed, cut off the exposed guards from the 

finished wall.

Shut off water supply. Remove plug(a) from base. Install two inlets(3) into two 

holes of the body(4). Tighten two screws(5) to secure the body. 

3

4

5

a

Отзывы: