Install or relocate the supply and outlet as necessary to comform to the roughing-in dimensions.

INSTALLATION

Important:

Toilet must have 305mm minimum rough-in to

install properly.

305mm

2

If replacing a toilet, remove the old wax.

3

Insert new T-bolts.
If installation of the new toilet is delayed, temporarily cover
the closet flange hole with a rag.

T

Do not use white cement or high lime content

cements to install this toilet. The expansion of cement due
to a rise in temperature may make the toilet crack or cause
damage. Kohler is not responsible for any damage caused
by installation with the use of cement.

NOTICE:

Closet
Flange

T-Bolts
T

Supply

696

135

140

1264349-T01-A

Содержание ADAIR K-5306T

Страница 1: ...Observe all local plumbing and building codes Shut off the water supply Seat post holes are on 140mm 5 1 2 centers Ensure that the new drain has the correct roughing in dimension This toilet has a 305...

Страница 2: ...ed If the existing toilet does not have a supply shut off valve below the tank install one before installing the new toilet Flexible hose are recommended to connect the supply line to the fill valve I...

Страница 3: ...sert new T bolts If installation of the new toilet is delayed temporarily cover the closet flange hole with a rag T Do not use white cement or high lime content cements to install this toilet The expa...

Страница 4: ...wax seal Wax Seal NOTE 1 NOTE 2 Wax ring type toilet gasket should not be installed at temperatures less than 21 If you are using a toilet gasket with an integral plastic sleeve make sure the gasket i...

Страница 5: ...m 11 Flush several times and check for leaks 12 Fill Float With Ballast Test flush the toilet Periodically check all connections for leaks for several days following installation Set the tank cover in...

Страница 6: ...r level Rotate screw clockwise and raise float to the desired water level Elevate water cup to a proper position as well Refer to float adjustment instructions b c Screw CLOSE Fasten the snap along CL...

Страница 7: ...e tank and tighten the flush valve nut if flush valve gasket is leaking Do not overtighten If leakage continues replace the gasket E Adjust the tank water level if it is too high 2 No Flush IMPORTANT...

Страница 8: ...ittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing c...

Отзывы: