![Kohler 24146IN-7 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/kohler/24146in-7/24146in-7_installation-instructions-manual_1986892007.webp)
7
1348773-IN2-A
1348773-IN2-A
*All settings to be done after opening glass panel
**Will reduce battery life considerably
Flushing Actuation Sensing
Distance
To change the flushing
sensing distance
Press the R button for <1s, the 2
LEDs flash quickly for 10s, put the
rear glass back in this duration. The
left LED will flash slowly, place hand
at desired distance in front of left
LED. The left LED flashes quickly
for 1s, the setting is then completed.
To follow, the right LED starts to
flash and similarly the half flush
sensing distance can be adjusted.
To cancel in middle of the setting,
press the R button.
Refilling Duration Adjustment To adjust the filling duration
indication for half and full flush
Press the M button for more than
3s, one full flush is executed and the
right LED start flashing along with
start of timer for the full flush filling.
At desired point, press M button for
<1s. The right LED stops flashing
and turns on for 2s. The duration
for full flush filling indicator has now
been set. Half flush duration is au
-
tomatically adjusted to 60% of full
flush duration.
Night Light**
To activate/de-activate
night light feature
If night light needs to be switched
on, press L button for >3s, both LED
lights turn on with dimmed bright-
ness. The lights stay on for next
7 hours. If night light needs to be
switched off within 7 hours, press L
button for >3s.
Hygiene Flush
To activate/de-activate
hygiene flush feature
(One flush every 4 hours)
To turn hygiene flush on, press R
button for >3s. The left LED will
flash 5 times. To turn off, press R
button for >3s, the right LED will
flash 3 times.
TROUBLESHOOTING
Symptoms
Probable causes
Corrective action
Right LED flashes in cycle(0.5s
ON, 1.5s OFF)
Battery voltage is lower than 2.4V
Replace batteries as soon as
possible
Touchless flushing not working 1. Battery might have died
2. Error in detection sensors
Use manual button in
emergency
User sensing distance reduced
Dark/non-reflective clothing
Stand closer to faceplate for
detection