1
1348773-IN2-A
FACEPLATE SPECIFICATION
INSTALLATION INSTRUCTIONS
SUMMON SENSOR
FP DC, MANUAL OVERRIDE
24146IN-7
BEFORE YOU BEGIN
• Please read these instructions carefully to familiarize yourself with the required tools, materials,
and installation sequences. Follow the sections that pertain to your particular installation. This
will help you avoid costly mistakes. In addition to proper installation, read all operating and
safety instructions.
• All information in these instructions is based upon the latest product information available at the
time of publication. Kohler India reserves the right to make changes in product characteristics,
packaging or availability at any time without notice.
• These instructions contain important care, cleaning, and warranty information -
please leave
instructions for the consumer.
•
In case product is damaged when unpacked for first time, please do not install and report to
customer care.
• Do not apply spares that are not provided by Kohler, and please note that glass adhesive tape
shall not be applied to the installation of Kohler spares. Kohler will not be responsible for any
damage related to installation with spares not provided by Kohler.
•
Faceplate is compatible only with pneumatic Instaflush tanks purchased after June 2019,
incase of older tank, order part - 1278771
* T&C depending on usage
Model
24146IN-7
Power
2 ‘D’ size Alkaline Batteries (3V DC)(not provided)
Consumption: < 21mAh/full flush cycle
Life: Minimum 10000 cycles*
User Sensing Distance
Default: 70cm
Adjustable: 70cm-100cm
Flushing Actuation Sensing Distance
0.5-10.2cm
Flushing Actuation Confirmation Time
0.5s
Refilling Duration Indicator
Full Flush: Adjustable(25s-300s)
Half Flush: 60% of Full Flush Time
Night Light
Default: Off
Hygiene Flush
Default: Off
Manual Flush Button
Yes (Behind Glass Panel)