background image

- 1 -

1. Safety precautions

DANGER

Expresses situations that can be clearly 

predicted as dangerous. If the noted danger is 

not avoided, it could result in death or serious 

injury.

It could also result in damage or destruction of 

assets.

WARNING

Expresses situations that, while not immediately 

dangerous, could become dangerous. If the 

noted danger is not avoided, it could result in 

death or serious injury.

It could also result in damage or destruction of 

assets.

CAUTION

Expresses situations that, while not immediately 

dangerous, could become dangerous. If the 

noted danger is not avoided, it could result in 

light or semi-serious injury.

It could also result in damage or destruction of 

assets.

ATTENTION

While there is little chance of injury, this content 

refers to points that should be observed for 

appropriate use of the product.

1.1 

 Danger

●  Do not use in locations where explosives, flammables, or other 

dangerous substances are present. This product is not an 

explosion-proof type unit. Explosion or ignition may occur.

●  When any wiring, installation, or inspection work is to be 

carried out, make sure that the unit is disconnected from the 

power supply, otherwise, an accident, an electrical shock or a 

malfunction may be caused.

●  Never attempt to remodel the product. It could result in abnormal 

operation leading to injury, electric shock, fire, etc.

●  Do not splash water on the product. Spraying it with water, 

washing it, or using it underwater could result in malfunction of 

the product leading to injury, electric shock, fire, etc.

●  If the equipment is used in a manner not specified by the 

KOGANEI, the protection provided by the equipment may be 

impaired.

1.2 

 Warning

●  Do not use the product in excess of its specification range. Doing 

so creates the risk of product breakdown, loss of function, or 

damage. It could also drastically reduce the operating life.

●  Because this product is used to detect objects, it does not have 

control functions meant for accident prevention or for other safety 

assurance purposes.

1.3 

 Attention

●  When the product can no longer be used or is no longer 

necessary, dispose of the consumables appropriately as industrial 

waste.

●  Do not touch the pressure sensor head when power supply is on.

2. Product overview

This product is a device that connects to and displays the values 

from sensor devices that have pressure, flow rate, and a variable 

1- to 5-volt DC output. It can also receive output from sensor 

devices and control its output according to those values.

You can also select either the RS-232C communication type or 

the RS-485 communication type, depending on your use and 

purpose.

      If any sensors except our pressure sensors (MSU-PH-

) are 

connected to the controller, UL authentication is limited to the 

controller.

3. Contents of the product set

When you receive this product, before you use it, check 

whether there are any missing items, and whether there were 

any abnormalities or damages that occurred during shipping. If 

there are damages, or if the product does not operate normally, 

contact your retailer (agent) or our nearest sales office.

3.1  Contents in the package

 

 The multi-channel, multi-sensor controller  1

 

  Owner's Manual

 

English 1

 

  Owner's Manual

 

Japanese 1

 

  Other accessories, cables, mounting brackets, and panel 

mounting parts are included according to the model.

Owner's Manual

Multi-Channel, Multi-Sensor Controller [MSU]

Thank you for purchasing this Koganei product. Please read this instruction manual carefully before using the device, so that you can use 

it safely and correctly. In addition, keep this manual in a safe place.For product handling and precautions, refer to “Safety Precautions” and 

“Handling Instructions and Precautions” in “Catalog No. A5046” before using.

M140821

Ver. 1.3

Содержание MSU-PH-EA Series

Страница 1: ...ct breakdown loss of function or damage It could also drastically reduce the operating life Because this product is used to detect objects it does not have control functions meant for accident prevention or for other safety assurance purposes 1 3 Attention When the product can no longer be used or is no longer necessary dispose of the consumables appropriately as industrial waste Do not touch the ...

Страница 2: ...ng for turning LEDs off peak hold bottom hold Filter Applicable to both SW output and display OFF to level 7 Main unit keys Up key Down key Enter key Communication Communications standard RS232C RS485 Communication speed 9600 19200 bps 9600 19200 38400 57600 115200 bps Address settings None Rotary switches Number of daisy chain connections Not applicable MAX 16 Item Specifications General Operatin...

Страница 3: ...5 Address setting 0 to F Note 1 Sensor connector RS 485 communication connector Power switch output connector Power switch output RS 232C communication connector Sensor connector M2 6 6 Depth 6 40 40 MSU kPa mL min L min 1 2 3 4 SW CH C B 7 8 9 A 4 5 6 01 2 3 D E F MSU kPa mL min L min 1 2 3 4 SW CH RS 485 communication specification 5 30 32 8 3 27 6 2 65 Address setting 0 to F Note 1 Sensor conne...

Страница 4: ...pin RXD white 9 pin TXD red 10 pin N C 11 pin N C Made by SUMITOMO 3M 37104 3101 Data input 1 pin V brown 2 pin Sensor output black 3 pin 0V blue 4 pin IN Note MSU 232 only Sensor head mounting dimensions For 2 pcs mounting Surface roughness Ry6 3 Note The sensor head MSU PH comes with 2 mounting screws M2 0 4 length 13 Note The sensor head MSU PH comes with 2 mounting screws M2 0 4 length 13 3000...

Страница 5: ...ect Sensor head and connector connection procedure 50mm 50mm 1 97 in No on the connector 1 2 3 4 Color of lead wire Sensor head brown wire Sensor head black wire Sensor head blue wire Prepared by customer AWG 24 26 0 14 0 3sq Insulation diameter φ0 8 1 0 mm 0 031 0 039 in Signal name Sensor head power supply Sensor head voltage output Sensor head power supply 0V Reference pressure capture To mount...

Страница 6: ...232C communication cable Black 0V white RXD Red TXD Host device with RS 232C built in R1 innter circuit RS 232C type 1 2 3 RS 485 communication cable White A Pink B Yellow 0V Host device with RS 485 built in RS 485 type 1 2 3 IN2 1 2 3 4 R 2 IN3 1 2 3 4 R 3 IN4 1 2 3 4 R 4 F Load Load Load Sensor head Channel 2ch Sensor head Channel 3ch Sensor head Channel 4ch Brown V Blue 0V Brown V Blue 0V Brown...

Страница 7: ...rmat 3 PSU 36W format 4 PSU 40W format Sensor head type settings Select a sensor head type to connect to each channel 0 Any sensor set display at 1 V and 5 V 1 MSU PH EA 101 3 to 0 0 kPa 2 MSU PH ER 100 0 to 220 0 kPa 3 MSU PH EM 100 to 1000 kPa 4 FS R05 500 to 500 mL min 5 FS R3 3 00 to 3 00 L min 6 FS 10 0 00 to 10 00 L min After changing the sensor head type the threshold value is initialized t...

Страница 8: ...ange while rising 3 Window comparator mode Mode for turning output ON within the set value range for L1 and L2 OFF point depends on response differential setting 4 High mode Mode for turning output ON when above the ON point OFF point depends on response differential setting 5 Low mode Mode for turning output ON when below the ON point OFF point depends on response differential setting Hysteresis ...

Страница 9: ...witch output L1 L2 Hysteresis ON t Window comparator mode L1 L2 Hysteresis H2 Hysteresis H1 High Mode L1 Hysteresis H1 Low Mode L1 Hyste To use Window Comparator Mode 1 and Window Comparator Mode setting must be L1 L2 L1 L2 Hysteresis H2 Hysteresis H1 High Mode L1 Hysteresis H1 Low Mode L1 Hysteresis H1 Output inversion settings Inversion or no inversion of the switch output 0 no inversion 1 Inver...

Страница 10: ...s Lr the same as when used in window comparator mode High mode and Low mode ΔL settings ΔL settings in import reference mode Threshold value Lr is set by importing a reference Threshold value Lr reference value ΔL Response differential settings Response differential settings for window comparator mode as well as High and Low mode H1 response differential for threshold value L1 ON point L1 OFF poin...

Страница 11: ...sure values that the LCD displays switch every second from channel 1 channel 2 channel 3 channel 4 channel 1 1 Channel 1 display 2 Channel 2 display 3 Channel 3 display 4 Channel 4 display Display update cycle Set the update cycle for the LCD display only applicable for measurement mode 1 125 ms 2 250 ms 3 500 ms 4 1000 ms Input channel Do settings to assign sensor input channels Set if output set...

Страница 12: ...ions Measurement mode Buttons that are pressed simultaneously for main unit operations are considered to be pressed until after all the buttons are released Switching display channels Switch display channels by using the or buttons The CH LED lights during display CH CH CH CH button button button button button button button button Auto scan mode Start or release auto scan mode by simultaneously pr...

Страница 13: ...o adjustment save location For configuring the communication speed setting and communication compatibility settings RS 232 Type only When there is no communication function 9 SCo does not appear Information Sensor Output Threshold Response Display External Input Hold Zero Adjust Serial Communication Pressing and holding the button on the setting mode selection screen takes you back to measurement ...

Страница 14: ...aces Configures display settings of any sensor when SE 0 is selected SW Decimal point position setting CH Setting channel lights SW Display setting for 5V CH Setting channel lights SW Allowable input range 9999 to 9999 Initial Default 1000 Display setting for 1V CH Setting channel lights SW Unit Segment Indicator Lights None kPa L min mL min Switches the segment next to the unit Display unit setti...

Страница 15: ...t CH Setting channel lights CH1 Channel 1 CH2 Channel 2 CH3 Channel 3 CH4 Channel 4 ALL Simultaneous setting of channels 1 through 4 SEQU Sequential setting of channels 1 through 4 oFF Disabled on Enabled Selects whether to enter the reference import mode SW Reference import mode selection CH Setting channel lights SW Returns to oFF No inversion on Inversion Switch output inversion selection CH Se...

Страница 16: ...alue setting L2 Select using or Configures the L2 threshold value setting H1 Select using or Configures the H1 hysteresis setting H2 Select using or Configures the H2 hysteresis setting dL Select using or Configures the ΔL reference import setting Reference Select using or Performs reference import Lr Displays the threshold value for reference input Lr Returns to SW Setting value input CH Setting ...

Страница 17: ...lter Level 2 FL3 Filter Level 3 FL4 Filter Level 4 FL5 Filter Level 5 FL6 Filter Level 6 FL7 Filter Level 7 Configures filter settings SW Filter setting selection CH Setting channel lights SW button button button button button button button 5 Display LED light setting backlight setting display refresh interval setting LED light setting selection LED Select using or of of CH LED SW LED unlit on on ...

Страница 18: ...t selection CH Setting channel lights SW Hold setting is canceled Hold OFF following power off button button button 8 Adjust Zero adjustment execution zero adjustment clear zero adjustment retention setting Setting channel selection Adjust Select using or CH Setting channel lights CH1 Channel 1 CH2 Channel 2 CH3 Channel 3 CH4 Channel 4 ALL Batch setting of channels 1 through 4 Executes zero adjust...

Страница 19: ...on speed setting Communication format setting selection Communication Format oFF MSU format PSU PSU format FSU FSU format P36 PSUー36W format P40 PSUー40W format Configures the communication format compatibility setting SW CH SW CH button button button button button 0 Information Version check setting initialization Version display Version Select using or Displays the version Initialization executio...

Страница 20: ...itive When sending commands in succession send the next command after receiving a response from the command you sent For information on communications settings for PLC computers etc refer to the user s manual for the device or software you are using Each setting of a type that has a communication function can also be done with support software Please download the support software from our website ...