Koganei IB Series Скачать руководство пользователя страница 2

Handling Instructions and Precautions

Specifications

Electrical Specifications

Mass

Rated voltage

Item

24 VDC

Applicable voltage range

V

21.6 to 26.4 (24±10%)

Current (when rated voltage applied) mA

23

Power consumption

W

0.55

Allowable circuit leakage current mA

1.0

Type of insulation

B type

Insulation resistance 

Note

100 or over

Color of LED indicator

Red

Surge protection (standard equipment)

Flywheel diode

Note: Value at 500 VDC Megger

Remark: Specification values are based on Koganei test standards.

Notes 1: The effective cross section values are calculated values, and are not measured values.

 

2: The valve when air pressure is 0.5 MPa [73 psi].

Item 

Model

IBZR8-4E1

IBZR8-4E2

Number of positions

2 positions

Number of ports

5

Valve function

Single solenoid

Double solenoid

Medium

Air

Operation system

Internal pilot type

Flow rate 

characteristics

Sonic conductance C 

dm

3

/(s·bar)

mm        J42:0.8、J62:1.6、J82:2
in         J5/32:0.8、J1/4:1.6、J5/16:2

Effective cross section area [Cv value] 

Note 1

  mm

2

 [Cv]

mm  J42:4〔0.22〕、J62:8〔0.44〕、J82:10〔0.56〕
in    J5/32:4〔0.22〕、J1/4:8〔0.44〕、J5/16:10〔0.56〕

Connection port size

Supply port 

φ

10 [0.394], outlet port 

φ

4 [0.157], 

φ

6 [0.236], 

φ

8 [0.315]

Supply port 

3/8、

outlet port 

5/32、1/4、5/16

Lubrication

Not required

Operating pressure range 

MPa [psi]

0.2 to 0.7 [29 to 102]

Proof pressure 

MPa [psi]

1.05 [152]

Operating temperature range (atmospheric and medium)  ℃ [℉]

5 to 50 [41 to 122]

Response time 

Note 2

 on/off time 

ms

15/30 or less

30 or less

Maximum operating frequency 

Hz

5

Shock resistance 

m/s

2

 [G]

294.2 [30]

Mounting direction

Unrestricted

Model

Mass

IBZR8-4E1

J42: 59 [2.08], J62: 60 [2.12], J82: 63 [2.22]

J5/32

:59

[2.08]

J1/4

:60

[2.12]

J5/16

:63

[2.22]

IBZR8-4E2

J42: 75 [2.65], J62: 75 [2.65], J82: 78 [2.75]

J5/32

:75

[2.65]

J1/4

:75

[2.65]

J5/16

:78

 [2.75]

IBZR8Z-E (end block)

81 [2.86]

IBZR8Z-E3/8

81 [2.86]

g [oz]

24 VDC

Internal circuit 

1.  Do not apply megger between the pins.

2.  Malfunctions, such as the solenoid valve not returning to normal, may occur 

if there is a leakage current within the circuit. Always use it at less than the 

allowable leakage current shown in the solenoid specifications. If circuit 

conditions, etc. cause the leakage current to exceed the maximum 

allowable leakage current, consult us.

3.  For the double solenoid configuration, avoid energizing both solenoids 

simultaneously.

NOTE

NOTE

NOTE

Solenoid with LED indicator and surge suppression

(-)

(+)

Lead wire

Red

Lead wire

Black

(Red)

Attaching and removing plug connector

Use fingers to insert the connector into the pin, push it in until the lever claw 

latches onto the protruded section of the connector housing, and complete the 

connection.

To remove the connector, squeeze the lever along with the connector, lift the 

lever claw up from the protruded section of the connector housing, and pull it out.

Crimping of connecting lead wire and contact

To crimp lead wires into contacts, strip off 4 mm [0.16 in] of the insulation from 

the end of the lead wire, insert it into the contact, and crimp it. Be sure at this 

time to avoid catching the insulation on the exposed wire crimping section.

Attaching and removing contact and connector

Insert the contact with lead wire into a plug connector 

 hole until the 

contact hook latches on and is secured to the plug connector. Confirm 

that the lead wire cannot be easily pulled out.

To remove it, insert a tool with a fine tip (such as a small screwdriver) 

into the rectangular hole on the side of the plug connector to push up 

on the hook, and then pull out the lead wire.

1.

  Do not pull hard on the lead wire. It could result in defective contacts, 

breaking wires, etc.

2.

  If the pin is bent, use a small screwdriver, etc. to gently straighten out the 

pin, and then complete the connection to the plug connector.

1.

  Do not pull hard on the lead wire.

2.

  Always use a dedicated tool for crimping of connecting lead wire and contact.

  Contact: 

Model 702062-2M

   

Manufactured by Sumiko Tech, Inc.

  Crimping tool:   Model F1-702062

   

Manufactured by Sumiko Tech, Inc.

Protrusion

Pin

Housing

Lever

Connector

Indication of 
polarity(DC)

Contact

Connector assembly

KSB0352Z

Hook

Exposed wire 
crimping section

Insulation crimp tab

Insulation (Maximum outer diameter: 

φ

1.7 [0.067])

Lead wire
Equivalent to AWG#22

#28

Exposed wire 4 mm [0.16 in]

Contact

KSB0353Z   

To operate the manual override, press it all the way down.

For the single solenoid, the valve works the same as when in the energized 

state as long as the manual override is pushed down, and returns to the rest 

position upon release.

For the double solenoid, pressing the manual override on the 14 (SA) side 

switches the 14 (SA) to the energized state, and the unit remains in that state 

even after the manual override is released. To return it to the rest position, 

operate the manual override on the 12 (SB) side. This is the same for the 

solenoid 12 (SB).

PUSH

NOTE

1.

  The  iB-ZERO series uses pilot type solenoid valves, so if you do not 

supply air to the 1 (P) port, the main valve will not change, even if 

you operate the manual override.

2.

  Do not attempt to operate the manual override with a pin or other 

object having an extremely fine tip. It could result in damage to the 

manual override.

Manual override

mm

in

mm

in

mm

in

Identification of quick fitting size

Tube size unit 

Release ring color

mm size

Ivory

in size

Milk white

Содержание IB Series

Страница 1: ... Instant assembly quick delivery Easy assembly 5 port manifold solenoid valve Valve width 18 mm 0 709 in Exhaust port Integrated muffler NEW OPTION PAT PEND The first in the world Integrally molded all plastic body 15 mm 0 591 in 35 3 mm 1 390 in Thin and lightweight Nearly 40 smaller Nearly 57 less mass than the previous 180 series manifold Quick fitting for Inch tube added 5 32 inch 1 4 inch 5 1...

Страница 2: ...protruded section of the connector housing and complete the connection To remove the connector squeeze the lever along with the connector lift the lever claw up from the protruded section of the connector housing and pull it out Crimping of connecting lead wire and contact To crimp lead wires into contacts strip off 4 mm 0 16 in of the insulation from the end of the lead wire insert it into the co...

Страница 3: ...old format Piping block Manifold model Model of mounted valve Valve specifications Valve specifications Specifications for fittings of pipe ports Wiring specification Specificationsforfittingsofpipeports Wiring specification Voltage Voltage Right side Left side 4E1 5 port 2 position single solenoid 4E2 5 port 2 position double solenoid 4E1 5 port 2 position single solenoid 4E2 5 port 2 position do...

Страница 4: ...mm 39 in 3 3000 mm 118 in Order codes EAZ 1W P Red Black Black Black Black Black Red Common wires Black Common wires Branch wire red NOTE NOTE 1 Due to the relative length of the branch wires for common wire connections connections cannot be done if two or more intermediate piping blocks are mounted between valves 2 When connecting common wires between double solenoid valves on the 12 SB side conn...

Страница 5: ...e between each valve and end block are secure We recommend adding intermediate piping blocks IBZR8Z PJ PJ3 8 if needed when there is a large number of valves or a large number of valves simultaneously supplying air to the secondary side Also be careful of actuator malfunctions caused by the exhaust pressure Furthermore both intermediate piping blocks IBZR8Z PJ PJ3 8 and valves can be added using t...

Страница 6: ...enoid 5 port double solenoid Single valve unit With quick fittings for mm tubes Manifold Intermediate piping block single unit Mounting example IBZRM4N stn 1 IBZR8 4E1 J42 PL 24 VDC stn 2 IBZR8 4E1 J62 PL 24 VDC stn 3 IBZR8 4E1 J82 PL 24 VDC stn 4 IBZR8 4E2 J82 PL 24 VDC 20 0 787 Exhaust port Exhaust port Integrated muffler Integrated muffler Same position on other side 72 3 2 846 35 1 378 5 3 0 2...

Страница 7: ... the manifold Then securely connect the hooks of both sides to the DIN rail from above and fix the position with DIN rail mounting screws When the DIN rail mounting bracket is selected the maximum is number of valves is 16 stations DIN rail mounting screw Fix with DIN rail mounting screw Tightening torque 0 74 N 0 55 ft lbf Same for other side DIN rail mounting bracket Main unit mounting screw Tig...

Страница 8: ...termediate piping block is mounted Exhaust port Integrated muffler Intermediate piping block Fitting 3 8 Exhaust port Integrated muffler Same position on other side 10 8 0 425 30 1 181 300 11 8 35 8 1 409 stn 1 stn 2 stn 3 stn 4 15 0 591 4 A Port 2 B Port Fitting 5 32 Fitting 1 4 Mounting screw 1 P Port 4 φ4 2 0 165 Oval hole Mounting hole Fitting 3 8 15 0 591 22 5 0 886 15 0 591 17 5 0 689 Pitch ...

Страница 9: ...193 131 6 5 18 77 2 3 039 4 A Port 28 3 1 114 15 0 591 102 4 016 72 3 2 246 15 0 591 35 3 1 39 30 1 181 10 8 0 425 300 11 811 s t n 1 s t n 2 s t n 3 s t n 4 J5 32 2 6 0 102 J1 4 3 4 0 134 J5 16 4 7 0 185 25 5 3 Exhaust port Integrated muffler Mounting screw Fitting 5 32 Fitting 1 4 Manualoverride Pitch LED indicator Numberofunits LNote QNote 1 55 2 165 77 3 031 2 70 2 756 94 3 701 3 85 3 346 109 ...

Страница 10: ...MEMO ...

Страница 11: ...MEMO ...

Страница 12: ...covers only such items supplied by KOGANEI CORP The products of other manufacturers are covered only by such warranties made by those original manufacturers even though such items may have been included as the components The specifications are subject to change without notice Warranty Period Koganei Responsibility Limitations URL http www koganei co jp E mail overseas koganei co jp 4 19 KG KOGANEI...

Отзывы: